Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 324

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Configuring Redundant Site Controller
In order for the Redundant Site Controller feature to work correctly, the Ethernet ports used
to connect the two Site Controllers need to be specifically configured. The correct IP address
for each Site Controller must be as specified below.
Site Controller 1 (SC1)
Site Controller 2 (SC2)
Procedure 8-28 How to Configure Ethernet Ports
1
2
3
4
5
8-48
Remember to check the configuration of both Site Controllers.
eth0: 10.0.253.1
eth1: 10.0.254.1
eth0: 10.0.254.2
eth1: 10.0.253.2
Reset the Site Controller and press the Esc key when prompted to interrupt the startup sequence.
From the prompt, run the command spr inet/if/eth0.
From the prompt, run the command spr inet/if/eth1.
Take note of the IP addresses and the MAC addresses.
If the IP addresses are set correctly (as stated in lists prior to this procedure),
continue to Step 7 below.
If the IP addresses are set incorrectly, they must be changed as follows in the next
step.
From the prompt, run the command spw inet/if/eth0 "dhcp:no
addr:10.0.(252+X).X mask:255.255.255.0 dev_name:tsec dev_unit:0
ethaddr:
yy:yy:yy:yy:yy:yy mtu:1500"
• There is one space between the ethaddr: and the
yy:yy:yy:yy:yy:yy in the command above.
• X = 1 for SC1, and 2 for SC2
• yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
Chapter 8: Site Controller
6802800U74-N September 2009