Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 390

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Base Radio Alarms
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_BRC_ABACUS_FS3_ALM
ALM_BRC_ABACUS_FS3_FAIL
ALM_RX_3_3_VOLT_FAULT
ALM_RX_DC_3_3V_FAIL
ALM_RX_5_VOLT
ALM_RX_DC_5V_FAIL
ALM_RX_12_VOLT
ALM_RX_DC_12V_FAIL
ALM_RX_27_VOLT_FAULT
ALM_RX_DC_27V_FAIL
13-24
Recovery
Description
Action
Abacus frame
BRC is de-keyed
sync 3 is
by the software.
not present -
the alarm is
reported as a
fault indication
message from
DSP.
The same as ALM_BRC_ABACUS_FS3_ALM
Receiver DC
Receiver is
3.3V line
disabled by
failure.
the software -
BRC is unable to
receive.
The same as ALM_RX_3_3_VOLT_FAULT
Receiver DC 5V
Receiver is
line failure.
disabled by
the software -
BRC is unable to
receive.
The same as ALM_RX_5_VOLT
Receiver DC
Receiver is
12V line failure.
disabled by
the software -
BRC is unable to
receive.
The same as ALM_RX_12_VOLT
Receiver DC
Receiver is
27V line failure.
disabled by
the software -
BRC is unable to
receive.
The same as ALM_RX_27_VOLT_FAULT
Chapter 13: MTS Troubleshooting
Clear Action
The alarm is
The alarm may be
cleared just after
reported because of
BRC is de-keyed.
the BRC hardware
failure.
If the alarm
The alarm may be
condition
reported because
disappears then
of some power
Receiver is
supply problems
re-enabled by
(cables, connectors)
the software.
or the BRC hardware
failure / configuration
problem.
If the alarm
The alarm may be
condition
reported because
disappears then
of some power
Receiver is
supply problems
re-enabled by
(cables, connectors)
the software.
or the BRC hardware
failure / configuration
problem.
If the alarm
The alarm may be
condition
reported because
disappears then
of some power
Receiver is
supply problems
re-enabled by
(cables, connectors)
the software.
or the BRC hardware
failure / configuration
problem.
If the alarm
The alarm may be
condition
reported because
disappears then
of some power
Receiver is
supply problems
re-enabled by
(cables, connectors)
the software.
or the BRC hardware
failure / configuration
problem.
6802800U74-N September 2009
Notes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4

Table of Contents