Preparation For Use - Stanley AV50 Instruction And Service Manual

Hydro-electric power tool
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
E N G L I S H

3.2 PREPARATION FOR USE

CAUTION - CORRECT PULL AND RETURN PRESSURES ARE IMPORTANT FOR PROPER FUNCTION OF THE ISTALLATION
TOOL. PERSONAL INJURY OR DAMAGE TO EQUIPMENT MAY OCCUR WITHOUT CORRECT PRESSURES. THE PULL AND
RETURN PRESSURES SUPPLIED BY THE HYDRAULIC PUMP UNIT MUST NOT EXCEED THOSE PRESSURES LISTED IN THE
PLACING TOOL SPECIFICATION.
IMPORTANT – BEFORE PUTTING THE PLACING TOOL AND HYDRAULIC HOSE SET INTO SERVICE:
ENSURE THAT THE PUMP PRESSURE RELIEF VALVES HAVE BEEN SET IN ACCORDANCE WITH THE PUMP INSTRUCTIONS
AND THE MAXIMUM PRESSURES SPECIFIED FOR THE PLACING TOOL AND HOSES.
ENSURE THAT THE HOSE KIT IS PRIMED WITH HYDRAULIC FLUID IN ACCORDANCE WITH THE PROCEDURE IN THE
PUMP INSTRUCTION MANUAL 07900-01030.
• Ensure the mains power supply to the hydraulic pump unit is switched off.
• Connect the placing tool hydraulic hose quick couplers directly to the pump unit before connecting the electrical control
cable. Hoses and control cable must be connected in this order and disconnected in reverse order.
• Switch on the mains supply to the hydraulic pump unit. Wait 5 seconds for the pump unit to complete the boot
sequence, before pressing the trigger switch. When all set the LCD screen on the pump unit will display 'AVDEL' .
• During the boot sequence the pump control system identifies any trigger operation as a potential malfunction and
prevents the motor from starting. The LCD screen will display 'BUTTON FAULT' in this instance. Reset by switching off the
power supply for 10 seconds.
• Ensure that the placing tool is positioned below the pump reservoir tanks. Depress and release the placing tool trigger
switch a few times to almost the full stroke of the tool to circulate hydraulic fluid and expel any air from the tool.
• Observe action of tool. Check for fluid leaks and ensure that in the idler mode the piston is in the fully forward position.
The placing tool will now be primed.
• Switch off the mains power supply to the hydraulic pump unit and then disconnect the placing tool from the pump unit
in reverse order to that described above.
• Now connect the placing tool to the primed hydraulic hose kit and electrical control cable. Then connect hydraulic hose
kit quick couplers and the electrical control cable to the pump unit.
• Attach the nose assembly to the tool as per the instructions in the relevant nose assembly datasheet.
• Switch on the mains supply to the hydraulic pump unit as described above.
• Depress and release the placing tool trigger switch a few times to almost the full stroke of the tool to circulate hydraulic
fluid.
• The placing tool is now ready for use.
10
O R I G I N A L I N S T R U C T I O N

Advertisement

Table of Contents
loading

This manual is also suitable for:

73435-02000

Table of Contents