Description
Use Program 10-23 : SIP System Interconnection Setup to determine if the system is
Program
interconnected and define the IP address of another system, call control port number and alias
address for SL2100 system interconnection.
10
Input Data
Item
No.
01
System Interconnection
02
IP Address
03
Call Control Port
04
Dial Number
05
Keep Alive mode for SIP
06
SIP Profile
Conditions
None
Feature Cross Reference
None
2-30
Program 10 : System Configuration Setup
10-23 : SIP System Interconnection Setup
System Number
Item
Input Data
0 = No (Disable)
1 = Yes (Enable)
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.255.255.254
1 ~ 65535
Character (Max 12)
0 = Disable
1 = Option Keep Alive Mode
1 = Profile 1
2 = Profile 2
3 = Profile 3
4 = Profile 4
5 = Profile 5
6 = Profile 6
Program 10 : System Configuration Setup
ISSUE 2.0
1 ~ 1000
Default
0
0.0.0.0
1720
No Setting