Error Processing; Errors Detected By The Analog I/O Unit - Omron CJ Series Operation Manual

Machine automation controller analog i/o units
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

1 Overview and Features
1-8

Error Processing

The following table shows the meanings of the indicator displays of the Analog I/O Unit. The contents
shown here are the same for all models. For error processing specific to each Unit, refer to 2-1-13 Error
Processing for CJ1W-PDC15, 3-1-12 Error Processing for CJ1W-AD04U, and 3-2-13 Error Processing
for CJ1W-PH41U.
1-8-1

Errors Detected by the Analog I/O Unit

ERC
RUN
Indicator
Indicator
(red)
(green)
Lit
Lit
Not lit
The following table shows the processing and results for Setting Parameter Group 1 (Continuously
Refreshed Parameters).
Processing
When an out-of-range set-
ting is made while power is
ON
When the setting is
changed within the allow-
able range during opera-
tion
1-42
Meaning
Probable cause
Setting Parameter
The Analog I/O Unit
Group 1
started up and was
(Continuously
operating properly,
Refreshed Parame-
but an out-of-range
ters) error
setting was made in
Setting Parameter
Group 1 (Continu-
ously Refreshed
Parameters) of the
Setting Parameters.
Setting Parameter
An out-of-range set-
Group 1 (Continu-
ting was made for
ously Refreshed
either Setting Param-
Parameters) or Set-
eter Group 1 (Contin-
ting Parameter Group
uously Refreshed
2 (Initial Settings
Parameters) or Set-
Parameters) error. Or,
ting Parameter Group
Expansion Setting
2 (Initial Settings
Parameters error.
Parameters) of the
Setting Parameters.
Result
The Unit continues operat-
ing with the Setting
Parameter Group 1 (Con-
tinuously Refreshed
Parameters) data prior to
the change.
The Unit operates with the
Setting Parameter Group
1 (Continuously
Refreshed Parameters)
data after the change.
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
Unit operation
The Unit continues
the operation with the
Setting Parameter
Group 1 (Continu-
ously Refreshed
Parameters) data
prior to the change.
The Unit will not start
up.
Indicators on Unit
ERC indicator is lit.
RUN indicator remains lit.
ERC indicator is not lit.
RUN indicator remains lit.
Remedy
Restore the set value
to within the allowable
range. (There is no
need to reset the
Controller or restart
the Unit.)
Restore the set value
to within the allowable
range, and then either
reset the Controller or
restart the Unit.
Device variable for CJ-
series Unit *_CfgErrAdr
The offset value from the
first word of the parameter
storing address where the
range error occurred is
output.
If there is no other error, 0
is output. (If there is
another error, the offset
value for that parameter
storing address is output.)