Omron CJ Series Operation Manual page 175

Machine automation controller analog i/o units
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

CJ-series
I/O memory address
DM No.
Bit No.
o+34
00 to 15
o+35
00 to 15
o+36
00 to 15
o+37
00 to 07
08 to 15
o+38
00 to 15
o+39
00 to 15
o+40
00 to 15
o+41
00 to 15
o+42
00 to 15
o+43
00 to 15
o+44
00 to 15
o+45
00 to 15
o+46
00 to 15
o+47
00 to 07
08 to 15
o+48
00 to 15
o+49
00 to 15
o+50
00 to 15
o+51
00 to 07
08 to 15
o+52
00 to 15
o+53
00 to 15
o+54
00 to 15
o+55
00 to 15
o+56
00 to 15
o+57
00 to 15
o+58
00 to 15
o+59
00 to 15
o+60
00 to 15
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
Variable (name)
Ch1_SqrtCfg
Ch1_InRateSpanValCfg_H
Ch1_InRateSpanValCfg_L
Ch1_RateCmpIntvlTm
Ch1_RateCmpUnit
Ch1_RateSclValCfg_H
Ch1_RateSclValCfg_L
Ch1_GainAdjFVCfg
Ch1_ZeroAdjFVCfg
Ch1_AdjPrd
Ch1_AdjNoticeDay
Ch1_TopVlyHystrs
Ch1_IntgUnit
Ch1_IntgCoef
Ch2_SqrtCfg
Ch2_InRateSpanValCfg_H
Ch2_InRateSpanValCfg_L
Ch2_RateCmpIntvlTm
Ch2_RateCmpUnit
Ch2_RateSclValCfg_H
Ch2_RateSclValCfg_L
Ch2_GainAdjFVCfg
Ch2_ZeroAdjFVCfg
Ch2_AdjPrd
Ch2_AdjNoticeDay
Ch2_TopVlyHystrs
NJ-series User-defined Variable
Description
Input No. 1 Square Root Extraction
Input No. 1 Maximum Rate-of-change
Range Value
Input No. 1 Minimum Rate-of-change Range
Value
Input No. 1 Rate-of-change Comparison
Time Interval
Input No. 1 Rate-of-change Comparison
Time Interval Unit
Input No. 1 Scaling Value for Maximum
Rate-of-change Range Value (Lower)
Input No. 1 Scaling Value for Maximum
Rate-of-change Range Value (Upper)
Input No. 1 Scaling Value for Minimum Rate-
of-change Range Value (Lower)
Input No. 1 Scaling Value for Minimum Rate-
of-change Range Value (Upper)
Input No. 1 Span Adjustment Position
Input No. 1 Zero Adjustment Position
Input No. 1 Zero/Span Adjustment Period
Input No. 1 Notice of Days Remaining
Input No. 1 Top and Valley Detection Hys-
teresis
Input No. 1 Integer Unit
Input No. 1 Integral Value Coefficient
Input No. 2 Square Root Extraction
Input No. 2 Maximum Rate-of-change
Range Value
Input No. 2 Minimum Rate-of-change Range
Value
Input No. 2 Rate-of-change Comparison
Time Interval
Input No. 2 Rate-of-change Comparison
Time Interval Unit
Input No. 2 Scaling Value for Maximum
Rate-of-change Range Value (Lower)
Input No. 2 Scaling Value for Maximum
Rate-of-change Range Value (Upper)
Input No. 2 Scaling Value for Minimum Rate-
of-change Range Value (Lower)
Input No. 2 Scaling Value for Minimum Rate-
of-change Range Value (Upper)
Input No. 2 Span Adjustment Position
Input No. 2 Zero Adjustment Position
Input No. 2 Zero/Span Adjustment Period
Input No. 2 Notice of Days Remaining
Input No. 2 Top and Valley Detection Hys-
teresis
Appendices
Data type
WORD
INT
INT
USINT
BYTE
DINT
DINT
UINT
INT
UINT
UINT
UINT
BYTE
BYTE
WORD
INT
INT
USINT
BYTE
DINT
DINT
UINT
INT
UINT
UINT
UINT
A-35