Omron CJ Series Operation Manual page 167

Machine automation controller analog i/o units
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

CJ-series
I/O memory address
DM No.
Bit No.
D(m+26)
00 to 15
D(m+27)
00 to 15
D(m+28)
00 to 15
D(m+29)
00 to 15
D(m+30)
00 to 15
D(m+31)
00 to 15
D(m+32)
00 to 15
D(m+33)
00 to 15
D(m+34)
00 to 15
D(m+35)
00 to 15
D(m+36)
00 to 15
D(m+37)
00 to 15
D(m+38)
00 to 15
D(m+39)
00 to 15
D(m+40)
00 to 15
D(m+41)
00 to 15
D(m+42)
00 to 15
D(m+43)
00 to 15
D(m+44)
00 to 15
D(m+45)
00 to 15
D(m+46)
00 to 15
D(m+47)
00 to 15
D(m+48)
00 to 15
D(m+49)
00 to 15
D(m+50)
00 to 15
D(m+51)
00 to 15
D(m+52)
00 to 15
D(m+53)
00 to 15
D(m+54)
00 to 15
D(m+55)
00 to 15
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
NJ-series device variable for CJ-series Unit
Variable (name)
*_Ch4_PVAlmValCfg_H
*_Ch4_PVAlmValCfg_L
*_Ch4_GainAdjPVCfg
*_Ch4_ZeroAdjPVCfg
*_Ch1_SensTypCfg
*_Ch1_InSpanValCfg_H
*_Ch1_InSpanValCfg_L
*_Ch1_PVUnitCfg
*_Ch1_SensErrCfg
*_Ch1_PVSclValCfg_H
*_Ch1_PVSclValCfg_L
*_Ch1_PVSclOfsValCfg
*_Ch1_AlmHystrsValCfg
*_Ch1_AlmOnDelayTmCfg
*_Ch1_AlmOffDelayTmCfg
*_Ch1_AveCfg
*_Ch2_SensTypCfg
*_Ch2_InSpanValCfg_H
*_Ch2_InSpanValCfg_L
*_Ch2_PVUnitCfg
*_Ch2_SensErrCfg
*_Ch2_PVSclValCfg_H
Description
Input No. 4 Process Value H (high limit)
Alarm Setting (Lower)
Input No. 4 Process Value H (high limit)
Alarm Setting (Upper)
Input No. 4 Process Value L (low limit)
Alarm Setting (Lower)
Input No. 4 Process Value L (low limit)
Alarm Setting (Upper)
Input No. 4 Gain for Span Adjustment
(Lower)
Input No. 4 Gain for Span Adjustment
(Upper)
Input No. 4 Zero Adjustment Value (Lower)
Input No. 4 Zero Adjustment Value (Upper)
Input No. 1 Input Signal Type Setting
Input No. 1 Maximum Value in Range
Input No. 1 Minimum Value in Range
Input No. 1 Temperature Unit
Input No. 1 Data Overrange Direction for
Sensor Error
Input No. 1 Scaling Value for Maximum
Value in Range (Span) (Lower)
Input No. 1 Scaling Value for Maximum
Value in Range (Span) (Upper)
Input No. 1 Scaling Value for Minimum
Value in Range (Zero) (Lower)
Input No. 1 Scaling Value for Minimum
Value in Range (Zero) (Upper)
Input No. 1 Scaling Offset (Lower)
Input No. 1 Scaling Offset (Upper)
Input No. 1 Alarm Hysteresis
Input No. 1 Alarm ON-delay Time
Input No. 1 Alarm OFF-delay Time
Input No. 1 Number of Values for Calculat-
ing Moving Average for Mean Value Pro-
cessing
Input No. 2 Input Signal Type Setting
Input No. 2 Maximum Value in Range
Input No. 2 Minimum Value in Range
Input No. 2 Temperature Unit
Input No. 2 Data Overrange Direction for
Sensor Error
Input No. 2 Scaling Value for Maximum
Value in Range (Span) (Lower)
Input No. 2 Scaling Value for Maximum
Value in Range (Span) (Upper)
Appendices
Data type
DINT
DINT
UDINT
DINT
UINT
INT
INT
WORD
WORD
DINT
DINT
DINT
UINT
UINT
UINT
UINT
UINT
INT
INT
WORD
WORD
DINT
A-27