Special I/O Unit DM Area (Device Variables for CJ-series Unit)
CJ-series
I/O memory address
DM No.
Bit No.
D(m)
00 to 15
D(m+1)
00 to 15
D(m+2)
00 to 15
D(m+3)
00 to 15
D(m+4)
00 to 15
D(m+5)
00 to 15
D(m+6)
00 to 15
D(m+7)
00 to 15
D(m+8)
00 to 15
D(m+9)
00 to 15
D(m+10)
00 to 15
D(m+11)
00 to 15
D(m+12)
00 to 15
D(m+13)
00 to 15
D(m+14)
00 to 15
D(m+15)
00 to 15
D(m+16)
00 to 15
D(m+17)
00 to 15
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
NJ-series device variable for CJ-series Unit
Variable (name)
*_LoadDefaultCfg
*_CfgErrAdr
*_Ch1_PVAlmValCfg_H
*_Ch1_PVAlmValCfg_L
*_Ch1_GainAdjPVCfg
*_Ch1_ZeroAdjPVCfg
*_Ch2_PVAlmValCfg_H
*_Ch2_PVAlmValCfg_L
*_Ch2_GainAdjPVCfg
*_Ch2_ZeroAdjPVCfg
*_Ch3_PVAlmValCfg_H
*_Ch3_PVAlmValCfg_L
*_Ch3_GainAdjPVCfg
*_Ch3_ZeroAdjPVCfg
*_Ch4_PVAlmValCfg_H
*_Ch4_PVAlmValCfg_L
*_Ch4_GainAdjPVCfg
*_Ch4_ZeroAdjPVCfg
Description
Default Block Read Command
Address of Data Range Error
Input No. 1 Process Value H (high limit)
Alarm Setting (Set at Process Value scaling
value.)
Input No. 1 Process Value L (low limit)
Alarm Setting (Set at Process Value scaling
value.)
Input No. 1 Gain for Span Adjustment
Input No. 1 Zero Adjustment Value (Set at
process value scaling value.)
Input No. 2 Process Value H (high limit)
Alarm Setting (Set at Process Value scaling
value.)
Input No. 2 Process Value L (low limit)
Alarm Setting (Set at Process Value scaling
value.)
Input No. 2 Gain for Span Adjustment
Input No. 2 Zero Adjustment Value (Set at
process value scaling value.)
Input No. 3 Process Value H (high limit)
Alarm Setting (Set at Process Value scaling
value.)
Input No. 3 Process Value L (low limit)
Alarm Setting (Set at Process Value scaling
value.)
Input No. 3 Gain for Span Adjustment
Input No. 3 Zero Adjustment Value (Set at
process value scaling value.)
Input No. 4 Process Value H (high limit)
Alarm Setting (Set at process value scaling
value.)
Input No. 4 Process Value L (low limit)
Alarm Setting (Set at process value scaling
value.)
Input No. 4 Gain for Span Adjustment
Input No. 4 Zero Adjustment Value (Set at
process value scaling value.)
Appendices
Data type
UINT
UINT
INT
INT
UINT
INT
INT
INT
UINT
INT
INT
INT
UINT
INT
INT
INT
UINT
INT
A-21