Omron CJ Series Operation Manual page 176

Machine automation controller analog i/o units
Hide thumbs Also See for CJ Series:
Table of Contents

Advertisement

Appendices
CJ-series
I/O memory address
DM No.
Bit No.
o+61
00 to 07
08 to 15
o+62
00 to 15
o+63
00 to 15
o+64
00 to 15
o+65
00 to 07
08 to 15
o+66
00 to 15
o+67
00 to 15
o+68
00 to 15
o+69
00 to 15
o+70
00 to 15
o+71
00 to 15
o+72
00 to 15
o+73
00 to 15
o+74
00 to 15
o+75
00 to 07
08 to 15
o+76
00 to 15
o+77
00 to 15
o+78
00 to 15
o+79
00 to 07
08 to 15
o+80
00 to 15
o+81
00 to 15
o+82
00 to 15
o+83
00 to 15
o+84
00 to 15
o+85
00 to 15
o+86
00 to 15
o+87
00 to 15
A-36
Variable (name)
Ch2_IntgUnit
Ch2_IntgCoef
Ch3_SqrtCfg
Ch3_InRateSpanValCfg_H
Ch3_InRateSpanValCfg_L
Ch3_RateCmpIntvlTm
Ch3_RateCmpUnit
Ch3_RateSclValCfg_H
Ch3_RateSclValCfg_L
Ch3_GainAdjFVCfg
Ch3_ZeroAdjFVCfg
Ch3_AdjPrd
Ch3_AdjNoticeDay
Ch3_TopVlyHystrs
Ch3_IntgUnit
Ch3_IntgCoef
Ch4_SqrtCfg
Ch4_InRateSpanValCfg_H
Ch4_InRateSpanValCfg_L
Ch4_RateCmpIntvlTm
Ch4_RateCmpUnit
Ch4_RateSclValCfg_H
Ch4_RateSclValCfg_L
Ch4_GainAdjFVCfg
Ch4_ZeroAdjFVCfg
Ch4_AdjPrd
Ch4_AdjNoticeDay
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
NJ-series User-defined Variable
Description
Input No. 2 Integer Unit
Input No. 2 Integral Value Coefficient
Input No. 3 Square Root Extraction
Input No. 3 Maximum Rate-of-change
Range Value
Input No. 3 Minimum Rate-of-change Range
Value
Input No. 3 Rate-of-change Comparison
Time Interval
Input No. 3 Rate-of-change Comparison
Time Interval Unit
Input No. 3 Scaling Value for Maximum
Rate-of-change Range Value (Lower)
Input No. 3 Scaling Value for Maximum
Rate-of-change Range Value (Upper)
Input No. 3 Scaling Value for Minimum Rate-
of-change Range Value (Lower)
Input No. 3 Scaling Value for Minimum Rate-
of-change Range Value (Upper)
Input No. 3 Span Adjustment Position
Input No. 3 Zero Adjustment Position
Input No. 3 Zero/Span Adjustment Period
Input No. 3 Notice of Days Remaining
Input No. 3 Top and Valley Detection Hys-
teresis
Input No. 3 Integer Unit
Input No. 3 Integral Value Coefficient
Input No. 4 Square Root Extraction
Input No. 4 Maximum Rate-of-change
Range Value
Input No. 4 Minimum Rate-of-change Range
Value
Input No. 4 Rate-of-change Comparison
Time Interval
Input No. 4 Rate-of-change Comparison
Time Interval Unit
Input No. 4 Scaling Value for Maximum
Rate-of-change Range Value (Lower)
Input No. 4 Scaling Value for Maximum
Rate-of-change Range Value (Upper)
Input No. 4 Scaling Value for Minimum Rate-
of-change Range Value (Lower)
Input No. 4 Scaling Value for Minimum Rate-
of-change Range Value (Upper)
Input No. 4 Span Adjustment Position
Input No. 4 Zero Adjustment Position
Input No. 4 Zero/Span Adjustment Period
Input No. 4 Notice of Days Remaining
Data type
BYTE
BYTE
WORD
INT
INT
USINT
BYTE
DINT
DINT
UINT
INT
UINT
UINT
UINT
BYTE
BYTE
WORD
INT
INT
USINT
BYTE
DINT
DINT
UINT
INT
UINT
UINT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-pdc15Cj1w-ph41uCj1w-ad04u

Table of Contents