3 Isolated-type Universal Input Units
3-1-7

Setting Parameters (Device Variables for CJ-series Unit)

Device variable
Type
(name)
*_LoadDefaultCfg
UINT
Setting Parameter Group 1: Continuously Refreshed Parameters (parameters that can be changed regardless of the CPU Unit
mode) *1
Process value alarm settings
*_Ch#_PVAlmValCfg_H
INT
*_Ch#_PVAlmValCfg_L
INT
• Zero/span adjustment
*_Ch#_GainAdjPVCfg
UINT
*_Ch#_ZeroAdjPVCfg
INT
Setting Parameter Group 2: Initial Settings Parameters (Parameters that are changed when the Controller is reset or the Unit
is restarted) *1
Operation Settings
*_PVUnitCfg
BYTE
*_Ch1_PVUnitCfg
BOOL
*_Ch2_PVUnitCfg
BOOL
*_Ch3_PVUnitCfg
BOOL
*_Ch4_PVUnitCfg
BOOL
*_SensErrCfg
BYTE
*_Ch1_SensErrCfg
BOOL
*_Ch2_SensErrCfg
BOOL
*_Ch3_SensErrCfg
BOOL
*_Ch4_SensErrCfg
BOOL
3-8
R/W
Data range
Default
RW
0 or 12345
−32728 to +32767
RW
+32767
−32728 to +32767
−32768
RW
RW
0 to 32000
10000
−9999 to +9999
RW
RW
16#00 to 16#0F
16#00
RW
0 or 1
RW
0 or 1
RW
0 or 1
RW
0 or 1
RW
16#00 to 16#0F
16#00
RW
0 or 1
RW
0 or 1
RW
0 or 1
RW
0 or 1
CJ-series Analog I/O Units Operation Manual for NJ-series CPU Unit(W498)
Parameter contents
0
Default Block Read Command
Once this parameter is set, the following will occur when
the Controller is reset or the Unit is restarted.
0:
Operates with the setting parameters set from the
CPU Unit.
12345: Automatically sets the default values for the
setting parameters.
Process Value H (high limit) Alarm Setting (Set at process
value scaling value.)
Process Value L (low limit) Alarm Setting (Set at process
value scaling value.)
Gain for Span Adjustment (set value × 0.0001)
0
Zero Adjustment Value (Set at process value scaling
value.)
• Temperature input: Set value × 0.1 °C, or 0.1 °F
• Voltage or current input: Set value × 1 digit
A BYTE-type variable that includes
the following BOOL-type variables:
0: °C
0
Input No. 1 Tem-
1: °F
perature unit
0
Input No. 2 Tem-
perature unit
0
Input No. 3 Tem-
perature unit
0
Input No. 4 Tem-
perature unit
A BYTE-type variable that includes
the following BOOL-type variables:
0
Input No. 1 Data
0: Upper
Overrange Direc-
1: Lower
tion for Sensor
Error
0
Input No. 2 Data
Overrange Direc-
tion for Sensor
Error
0
Input No. 3 Data
Overrange Direc-
tion for Sensor
Error
0
Input No. 4 Data
Overrange Direc-
tion for Sensor
Error
Bit number
0
1
2
3
Bit number
0
1
2
3