Input/Output Data - Furuno FAR-2117 Installation Manual

Marine radar/arpa
Hide thumbs Also See for FAR-2117:
Table of Contents

Advertisement

5. INPUT/OUTPUT DATA

Input and output data are shown in the table below.
Note: This radar accepts position data fixed by WGS-84 geodetic datum only. Set the
datum to WGS-84 on the EPFS (GPS, etc.) connected to this radar. If other type of datum is
input, the error message "DATUM" appears and the AIS feature is inoperative. Baud rate for
the serial input is automatically set to 4800, 9600, 19200 or 38400 as appropriate.
Input
Data
Heading signal
Speed signal
Navaid data
External radar
signal
Alarm ACK input
Track Control unit
Output
Radar system data
TT data*
ALARM data
Remote display
signal
External LCD
monitor signal
External CRT
monitor signal
Alarm signal
*The output sentence, mode and baud rate can be set at the TT Preset menu.
**Data cycle should be input with more than 40 Hz (HSC) or 20 Hz (normal speed).
Specifications
Contents
synchro or step
GC-10 required
AD-10 format
External AD-100
IEC 61162-2**
IEC 61162-1
IEC 61162-1
Position, course,
speed, LORAN-C TD,
waypoint, route, time,
wind data, current
data, depth,
temperature, roll,
pitch, ROT
Heading,
No STC control
Bearing, Trigger,
Video
Contact closure
IEC61162-1
ACK
RS-422
RS-232C
RSD, OSD, TLL,
IEC 61162-1
TTD, TTM
IEC 61162-1
ALR
HD, BP Trigger,
Video
DVI
Same as main display
unit
R, G, B, H, V
Same as main display
unit
Contact closure
Output to alarm system
by using photo-relay
IEC 61162-1
ALR
Remarks
AD-10 and
IEC 61162 are switched by
menu setting.
For IMO spec, IEC-61162-1
Edition 2 is required.
Operate as remote display
Input from alarm system
Input from alarm system
Option
For PC plotter
For ECDIS
For ALARM system
2 ports
2 systems in total
Option
4 systems, Output contents
are selected by menu.
Output to alarm system
5-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Far-2117-bbFar-2127Far-2127-bbFar-2817Far-2827

Table of Contents