2. WIRING
8. Nip the armor between two washers, and trim the excess armor from around washers.
And then pass the shield between the clamping ring and the washer as shown below.
Fasten the clamping ring with the screws.
9. Connect the signal cable to the terminal board TB801 and TB802 on the RFTB board
03P9349 by referring to the interconnection diagram. Keep "slack" in the coaxial wire to
prevent breakage. Insert the cores (except coaxial wire) to the connector with the opener.
Clamp the coaxial wire with cable clamp on the board 03P9349 as shown below.
10. Bind cable cores with cable ties.
2-4
Clamping ring
Washer
Rubber gasket (25B)
Armor
Signal cable entrance
1. Insert opener.
2. Push opener.
3. Insert a core.
4. Release opener.
Tighten conductor with screw.
4-M4x16
Shield
Opener
Clamp shield with bracket.