Hitachi Inverter Error Codes - Blodgett BCX14G Troubleshooting Manual

Combination oven steamer
Table of Contents

Advertisement

Error Code
Name
E01
Over current while at a constant speed
E02
Over current while decelerating
E03
Over current while accelerating
E04
Over current during other conditions
E05
Overload protection
E07
Overvoltage protection
E08
EEPROM Error
E09
Under Voltage Error
E11 / E22
CPU Error
E12
External Trip
E13
USP
E14
Ground Fault
E15
Input over voltage
E21
Thermal Trip
E35
Thermistor
---
Under voltage with no outputs present

Hitachi Inverter Error Codes

Description
The inverter output was short circuited , the motor shaft is locked ,
or the motor has a heavy load.
A motor overload is detected by the electronic thermal function of
the inverter.
The DC bus voltage exceeds the threshold due to regenerative energy
from the motor.
The EEPROM memory has problems due to noise or overheating.
The DC bus voltage drops below the threshold.
The CPU has malfunctioned.
An external trip was triggered at terminal 5.
The Unattended Start Protection is enabled and an error occurred
when a run signal is present.
The inverter sensed a ground fault between the outputs and the
motor during power up testing.
The input voltage exceeds the threshold 100 seconds after power up.
The inverter internal temperature exceeds the threshold.
The inverter sensed a high temperature signal from the optional
Thermistor between terminal 5 and CM1.
The inverter senses a low voltage input and no output is enabled.