Manual Control Factory Level Programming - Blodgett BCX14G Troubleshooting Manual

Combination oven steamer
Table of Contents

Advertisement

BCX, BX – NEW MANUAL CONTROL
(The oven needs to be in the "OFF" position)
Press the Timer Dial Till
Turn the Dial:
Press the Dial to Enter
Press the Dial to Enter
Press the Dial to Enter
Press the Dial to Enter
Press the Dial to View
Press the Dial to Retune
(CONTINUE)
P-##
(P-02)
Cool Down Temp
(P-03)
Ready Beep
(P-04)
Fan Reverse Time
(P-05)
Cook Done Beeper
(P-06)
Delime Interval
(P-07)
Flush Interval
(P-08)
Appliance Type
(P-09)
Machine Type
(P-10)
Max Steam On Demand
(P-11)
Min Hot Air Set Point
(P-12)
Max Hot Air Set Point
(P-13)
Min Steam Set Point
(P-14)
Max Steam Set Point
(P-15)
Max Core Probe Pull Temp
(P-16)
Upper Hot Air Hysteresis
(P-17)
Lower Hot Air Hysteresis
(P-18)
Upper Steam Hysteresis
(P-19)
Lower Steam Hysteresis
Factory Level Programming
Code: 3228
"0000" Is Displayed
Scroll the flashing # to (3)000
Scroll the flashing # to 3(2)00
Scroll the flashing # to 32(2)0
Scroll the flashing # to 322(8)
"P-01" Is Displayed
Turn Dial to: (F)
Turn Dial to: P-02
(FOLLOW STEPS ABOVE)
" Set To "
30 Hours
24 Hours
BCX / BX
15
100F
ON
6:00
Yes
Gas
20
140F
500
85F
225F
200F
1F
1F
1F
1F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bx14g

Table of Contents