Bcx14G Drain Valve Operation Troubleshooting From Jan 2007 To Sept 2010 - Blodgett BCX14G Troubleshooting Manual

Combination oven steamer
Table of Contents

Advertisement

BCX14G
BCX14G DRAIN VALVE OPERATION TROUBLESHOOTING
J8
J8-1
J8-2
IFB
Relay Board
J8-8
J8-9
The drain valve in its normally
closed position should always
have 24Dcv_Rtn_L input along
with the +24Dcv_H out put
from the IFB J8 connector to
the motorized drain valve.
The drain valve opens when the
+24Dcv_H switches from J8-8
to J8-9 then it should switch
back to close.
The drain valve will only open
when the logic board sends an
output signal to the IFB after
oven is cold and 4-5 hours of
non use, or when the flush
switch is activated at the IFB.
+24Dcv_H
24Dcv_Rtn
Drain_Closed_H
Drain_Open_H
OR-17
Y-9
FIGURE 10
100
BK-20
24Dcv_Rtn_L
5
1
3