Over-current Stall Prevention during operation

Settings
This parameter selects the percentage of allowable over-current during operation before
the stall prevention function is enabled.
If the output current exceeds the value specified in Pr.06-02 when the drive is operating at
steady state speed, the drive will decrease its output frequency to prevent the drive from
faulting with an OC. Once the current falls below the value specified in Pr.06-02, the drive
will then accelerate to catch up with the command frequency.
06 - 03

Over-torque Detection Selection

Settings
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Over-current Stall
Prevention during
acceleration
06-01
Over-current stall
prevention during
acceleration,
frequency held
Over-current Stall Prevention during Acceleration
20~150%
Over-current Stall
Prevention during
operation 06-02
Over-current Stall
Prevention during
operation, output
frequency decrease
Over-current Stall Prevention during Operation
00: Over-torque detection disabled.
01: Over-torque detection enabled during constant speed operation
(OL2), and operation continues.
02: Over-torque detection enabled during constant speed operation
(OL2), and operation halted.
03: Over-torque detection enabled during operation (OL2), and
operation continues.
04: Over-torque detection enabled during constant speed operation
(OL2), and operation halted.
Current
Output
frequency
Time
Current
Output
frequency
Time
5-31
VFD-F Series
Factory Setting: 120
Unit: 1
Factory Setting: 00
5