Delta Electronics AC Drive VFD-F Series User Manual page 135

Vfd-f series
Table of Contents

Advertisement

VFD-F Series
Other Functions
Protection
Built-in Reactor
Built-in Brake Chopper
Cooling Methods
Installation Location
Pollution Degree
Ambient Temperature
Storage/ Transportation
Temperature
Ambient Humidity
Vibration
AVR, 2 kinds of S-Curve, Over-Voltage, Over-Current Stall Prevention, Fault Records,
Reverse inhibition, DC Brake, Momentary Power Loss restart, Auto torque and slip
compensation, PID Control, Parameter Lock/Reset, Frequency Limits, Adjustable Carrier
Frequency, 4 sets of Fan & Pump Control,
Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating, External
Fault, Electronic thermal, Ground Fault, Phase-loss
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
-10
2
9.80665m/s
DC Reactor: 25~215HP
AC Reactor: 250~300HP
1~20HP
Forced Fan-cooled
2
o
o
C to 40
C Non-Condensing and not frozen
o
-20
C to 60
Below 90% RH (non-condensing)
(1G) less than 20Hz, 5.88m/s
A-2
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
o
C
2
(0.6G) at 20 to 50Hz

Hide quick links: