Diagnostic - Pentair AUTOTROL MAGNUM 293 Installer Manual

Table of Contents

Advertisement

6.4.6

Diagnostic

To access diagnostic values, press and hold
Diagnosti
c Code
H0
Initial setting value
H1
Day since last regeneration
H2
Current flow rate
H3
Water used today since time of regeneration
H4
Water used since last regeneration
H5
Total water used since reset in 100 s
H6
Total water used since reset in 1000000 s
H7
Average usage for Sunday
H8
Average usage for Monday
H9
Average usage for Tuesday
H10
Average usage for Wednesday
H11
Average usage for Thursday
H12
Average usage for Friday
H13
Average usage for Saturday
H14
Average service cycle
H15
Peak flow rate
H16
Day and time of peak flow rate
H17
Months since service
Hr
Number of regenerations since last service
Ref. MKT-IM-012 / D - 03.02.2022
Installer manual Autotrol Magnum 293 - 298 Logix 742-762 - Programming
and
Description
for 5 seconds to view the "H" levels.
Unit
Range
Litre
Resin Volume
N/A
0 - 255
Depends on turbine used
3
m
0 - 61310.70
3
m
0 - 61310.70
3
m
0 - 9999
3
m
4264 x 10
3
m
0 - 61310.70
3
m
0 - 61310.70
3
m
0 - 61310.70
3
m
0 - 61310.70
3
m
0 - 61310.70
3
m
0 - 61310.70
3
m
0 - 61310.70
Day
0 - 255
l/min
0 - 1000
Time and day that peak flow
occurred
Month
0 - 2184
N/A
0 - 65536
762
742
Yes
Yes
No
4
Yes
61 / 110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents