Parameters P16 to P19 are skipped on 742 controller.
6.4.3

Basic programming parameters (3 - Cycle filter system)

Parameter
description
P1
Time of day
P2
Day of week
P3
Time of
regeneration
P4
Calendar
override
P5
Day of week
regeneration
P6
Backwash time
P7
Capacity of unit
P8
-
* Default value selected with valve type and resin volume.
6.4.4

Advanced programming parameters (3 - Cycle filter system)

Parameter
description
P9 Units of measure
P10
Clock mode
P11 Service interval
58 / 110
Range of
Default
values
value
1:00 - 12:59
12:00 PM
AM
0:00 - 23:59
PM
N/A
None
1:00 -
2:00 AM
12:59AM
0:00 -
23:59PM
0 - 99
3
N/A
None
1 - 250
14
1 - 900
*
-
-
Range of
Default
values
value
0 - 1
**
0 - 1
**
0 - 250
0
Units of
measure
Hour :
Range depends on value
selected for P10.
minute
N/A
-
Hour :
Range depends on value
selected for P10.
minute
Days
0 = no calendar override.
0.5 = regeneration twice a day at
time of regeneration and
12 hours later.
Calendar override skipped if at
least one day of regeneration
selected.
N/A
Day of week regeneration is
skipped if calendar override is
more than 0 (742 controller
only).
Minutes
-
3
m
Unit of measure depends on
value selected for P9.
-
Skipped for 3 - cycle filter
configuration.
Units of
measure
N/A
0 = US unit.
1= Metric unit.
N/A
0 = 12 hours clock.
1 = 24 hours clock.
Month
Uses 30 days for each month.
Ref. MKT-IM-012 / D - 03.02.2022