(6) Monitor function

① The software version can be viewed with N01, N02, and N14
② Each part of the sewing machine during operation can be monitored with N03, N04, N05, N06, and N07.
③ Operation restrictions by grease-up error can be canceled with N15.
④ N21, N22, N23, N24 can be updated.
Item
N01 Main software version
N02 Panel software version
N03 Sewing machine speed
monitor
N04 Input value of pedal A/D
N05 Display of principal axis
angle
N06 Display of principal axis
angle
N07 Supply voltage A/D value
N14 ST software version
N15 Grease-up stich count
A
B
A
B
4) Hold down
⓬ for 3 seconds to display the memory switch.
5) Press
❻ in the state that the function setting No. A is blinking to select "N03 (N04, N05,
N06, N07)".
6)
Put the sewing machine in operation by pedal operation. Change in the contents on the display can be
viewed.
7) Press
⓬ to return the normal sewing state.
Level
Display before initial operation
U
Displays the main software version.
Displays the panel software version.
U
Measures the sewing machine speed
S
and displays it.
S
Displays the input value of pedal A/D.
S
S
Displays the A/D value of the supply
S
voltage.
Displays the version of the presser lifter
U
motor control software.
Displays the number of stiches when
S
greasing is necessary.
The counter can be cleared.
[1]
1) Activate the memory switch in the user level.
2) Press
3) Press
[2] Operation state monitoring
1) Activate the memory switch in the service level.
2)
3) Make the needle bar and presser lifter motor
– 86 –
Display after initial operation
Displays the angle when the up
stop position is zero degree.
Displays the angle when the down
stop position is zero degree.
Check of software version
(Refer to "4.-(2)-[1] User level".)
❻ in the state that the function
setting No. A is blinking to select "N01" (N02,
N03).
⓬ return the normal sewing state.
(Refer to "4.-(2)-[2] Service level".)
Press
⓬ to return the normal sewing
state.
conduct initial operation.
(The method of making them conduct initial
operation varies depending on the setting on P136.)