Adjustment Procedure
1) Method of lubrication
1. SH, SJ type (Specification for minute-quantity lubrication)
Face plate needle
bar lubrication :
Minute-quantity lubrication by the oil wick ❶.
Hook ❷
:
Forced lubrication by the plunger pump ❸
Quantity of oil can be adjusted by the hook
oil adjusting screw ❹.
Lubricant can be fed to the oil tank ❺
through the arm lubrication hole ❻.
2. MS type (Specification for semi-dry items)
Face plate needle
bar lubrication :
Lubrication by grease sealed in the needle
bar lower metal ❼.
Forced lubrication by the plunger pump ❸
Hook ❷
:
Quantity of oil can be adjusted by the hook
oil adjusting screw ❹ .
Lubricant can be fed to the oil tank ❺
through the arm lubrication hole ❻ .
Results of Improper Adjustment