2.5 Specifications for the Power Supply Module

2.5.1
G eneral Specification
1 9 B
AHPS05-5A
Item
Supply voltage
Maximum input
power
Action
specifications
Allowable
instantaneous
power failure time
Fuse
Inrush current
24 VDC output
Power protection
Maximum output
power
Surge voltage
withstand level
Insulation voltage
Ground
Weight
AHPS15-5A
Item
Supply voltage
Maximum input
power
Allowable
instantaneous
power failure time
Fuse
Inrush current
24 VDC output
Maximum output
power
Power protection
Surge voltage
withstand level
Ground
Weight
2 - 2 4
s
100~240 VAC (-15%~10%)
50/60 Hz±5%
100 VAC/1.2A~240 VAC/0.68A; 70 W
If the input power supply is larger than 85 VAC, the power supply module can
function normally.
If the instantaneous power failure time is within ten milliseconds, the power
supply module keeps running.
4 A/250 VAC
45 A within 1 millisecond at 115 VAC
The maximum current is 2.5 A.
It is only for a backplane.
The 24 VDC output is equipped with the short circuit protection and the
overcurrent protection.
60 W
1,500 VAC (Primary-secondary), 1,500 VAC (Primary-PE), 500 VAC (Secondary-
PE)
Above 5 MΩ
(The voltage between all inputs/outputs and the ground is 500 VDC.)
The diameter of the ground should not be less than the diameters of the cables
connected to the terminals L and N.
380g
24 VDC (-35%, +30%)
24 VDC / 2A; 48 W
10 milliseconds
6.3 A/250 VAC
30 A within 100 milliseconds
1.5 A
36 W
The 24 VDC output is equipped with the short circuit protection, the overcurrent
protection, and the overvoltage protection.
500 VAC
The diameter of the ground should be greater than 1.6 mm
380g
Specifications
Specifications
2
.

Advertisement

loading