DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
5.2.2

Mounting

Designation of the cable grommet (mount‐
ing/sealing kit)
QT11
QT12
QTB
Fig.5-9:
Cable diameter and corresponding cable grommet
The cables, which are lead through a cable grommet, are to be provided with
a strain relief. This can be realized e.g. with a cable wrap behind the grommet.
NOTICE
A cable grommet fitting to the cable diameter is to be used and to be mounted
properly. The sealing of the cover must not be damaged. The cover is to be
mounted properly and is to be fastened with the correct mounting torque, see
also
fig. 5-15 "Mounting torques" on page
Position of the connections
The connectors (③) are located under the housing cover (②), see
"Position of the connectors on the VDP 40.3 device" on page
1
2
On
Off
S1
1 2
Screws
Cover
Connectors (are located under the cover)
Fig.5-10:
Position of the connectors on the VDP 40.3 device
Dismounting the cover
Dismount the cover by loosening the screws (see the following illustration).
Bosch Rexroth AG
Dimensions, Installation and Wiring
Cable diameter
11-12 mm
12-13 mm
Blind grommet
Loss of IP degree of protection due to wrong
size and/or wrong mounting of the cable grom‐
met and damaged and/or wrongly mounted or
not sufficiently fastened covers.
35.
3
XVID
XSER
XUSB1/2
XUSB3/4
XUSBIN
33/81
fig. 5-10
33.
1
X1S1
24V