LED Display
Two-color: Blinking (amber)
Segment: 8
One-color: Off
Two-color: Blinking (amber)
Segment: A
One-color: Off
Two-color: Blinking (amber)
Segment: C (lower-case)
One-color: Off
Two-color: Blinking (amber)
Segment: L
One-color: Off
Two-color: Blinking (amber)
Segment: U
One-color: Off
Two-color: Off
Segment: L
One-color: On
Status and Action
Status
Interface error
Action
Check that the SAS cable is properly connected. If
the status does not change, replace the SAS cable. If
the problem still remains, this product or the SAS
card may fail.
Status
Cartridge memory data abnormal
Action
Eject and replace the data cartridge. If the problem
still remains after replacement, a failure may occur.
Status
An unusable cleaning cartridge was inserted.
Action
Press the Eject button to eject the cleaning cartridge
and insert a correct cleaning cartridge.
"5.1 Usable Cleaning Cartridge"(p.81)
Status
An error occurred when loading the data cartridge.
Action
Eject and replace the data cartridge. If the problem
still remains after replacement, a failure may occur.
Status
An error occurred when unloading the data car-
tridge.
Action
Eject and replace the data cartridge. If the problem
still remains after replacement, a failure may occur.
Status
The Eject button was pressed while application
software was running.
Action
Perform ejection using the application software.