Fujitsu PRIMERGY LTO4 User Manual page 64

Table of Contents

Advertisement

LED display specification list
The LED combinations are as follows. For LED details, refer to "7 Troubleshooting" ( p.85).
Two-color
LED
Off
On (green)
On (green)
Blinking
(green)
Blinking
(green)
On (green)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Blinking
(amber)
Off
*: The LED is not turned off until cleaning has normally completed (even if the server's power is
turned off, the LED is not turned off).
64
Segment
One-color
LED
LED
Off
Off
PowerOff: Power is not supplied to this product.
PowerOn (No cartridge): Power is supplied and a data cartridge can
Off
be inserted manually.
Ready: Power is supplied and a data cartridge is recognized by the
Off
Off
sensor. When the data cartridge has been loaded, this product can be
used.
Running: This product is loading/unloading, unwinding the data car-
Off
Off
tridge, or writing/reading data on the data cartridge.
C
Blinking
Cleaning
A write-protected cartridge or LTO2 (Read Only) cartridge was
P
Off
loaded.
F
Blinking
Updating the firmware.
C
On
Cleaning request (*): Needs cleaning.
1
Off
The temperature value is abnormal.
2
Off
The voltage value is abnormal.
3
Off
The firmware update failed.
4
Off
A drive hardware error was detected.
5
Off
A hardware abnormality was detected.
6
Off
The data cartridge is abnormal.
Incompatible cartridge inserted:
7
Off
A data cartridge whose format was incompatible (LTO1) was inserted.
8
Off
Interface error
A
Off
The data on the data cartridge memory is abnormal.
c
(lower-
Off
An unusable cleaning cartridge was inserted.
case)
L
Off
An error occurred when the data cartridge was loaded.
U
Off
An error occurred when the data cartridge was unloaded.
L
On
The Eject button was pressed while application software was running.