Viessmann Vitoligno 300-C Installation And Service Instructions Manual page 83

18 to 48 kw pellet boiler
Table of Contents

Advertisement

Code 1
(cont.)
Coding in the delivered condition
Feed screw conveyor maximum cycle
15:...
Max. cycle limit of feed screw con-
veyor
Day hopper idle runtime (manual charging)
27:....
Rotary lock valve idle runtime with
manual charging of the boiler
Code is only available with manual
charging of the boiler.
Vacuum module post-flushing time
2B:...
Run-on time of vacuum module
Code only available for charging
with mole.
Note
Risk of blockage
Day hopper idle runtime (autom. charging)
2C:...
Rotary lock valve emptying time
before vacuum module starts.
Code is only available for charging
with vacuum module.
Discharge cycle - ON
30:...
Cycle, discharge
(discharge runs for ... seconds)
Discharge cycle - OFF
31:...
Pause, discharge
Discharge delay
32:...
Discharge delay
External charging cycle - ON
40:...
External charging cycle
(external charging runs
for ... seconds)
External charging cycle - OFF
41:...
External charging pause
External charging delay
42:...
External charging delay
Possible change
15:...
Setting range in %
to
15:...
27:....
Setting range in minutes
to
27:....
2B:...
Setting range in minutes
to
2B:...
2C:...
Setting range in minutes
to
2C:...
30:2
Setting range in seconds
to
30:120
31:0
Discharge does not pause: Constant
operation
31:1
Setting range in seconds
to
31:100
32:0
Setting range in seconds
to
32:100
40:2
Setting range in seconds
to
40:120
41:0
External charging does not pause:
Constant operation
41:1
Setting range in seconds
to
41:100
42:0
Setting range in seconds
to
42:100
Codes
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vl3c

Table of Contents