Electrical connections
Connection options at HKK PCB and extension kits via KM-BUS
Key
HC
Heating circuit
SOL Solar circuit
TWE DHW heating
(UP) Additional function solar optional: Circulation pump for heat transfer of the DHW cylinder
(ZP) DHW circulation pump optional
Without solar
To HKK PCB of the control unit
Connection group
A1
1 heating circuit
HC1
with mixer
—
2 heating circuits
HC1
with mixer
—
HC1
3 heating circuits
HC1
with mixer
—
HC1
HC1
4 heating circuits
HC1
with mixer
HC1
HC1
1 heating circuit
HC1
with mixer
HC1
and TWE
—
—
2 heating circuits
HC1
with mixer
HC1
and TWE
HC1
—
HC1
—
3 heating circuits
HC1
with mixer
HC1
and TWE
HC1
HC1
HC1
—
4 heating circuits
HC1
with mixer
HC1
and TWE
HC1
(cont.)
A2
(ZP)
(ZP)
HC2
(ZP)
(ZP)
HC2
(ZP)
HC2
(ZP)
HC2
(ZP)
HC2
TWE + (ZP)
(ZP)
TWE + (ZP)
(ZP)
HC2
HC2
(ZP)
(ZP)
TWE + (ZP)
TWE + (ZP)
HC2
HC2
(ZP)
HC2
TWE + (ZP)
TWE + (ZP)
HC2
TWE + (ZP)
HC2
To "Extension kit for heating
circuit with mixer" (if instal-
led) via KM-BUS
E1
Rotary selector S1 setting
A3
1
—
—
HC1
—
(ZP)
—
HC1
—
HC2
—
HC3
—
HC1
—
(ZP)
HC3
HC2
—
HC3
HC4
HC2
—
(ZP)
HC3
—
—
TWE
—
HC1
—
HC1
—
TWE + (ZP)
—
(ZP)
TWE
HC2
—
HC1
—
HC2
—
HC1
—
HC3
TWE
(ZP)
HC3
HC2
—
TWE + (ZP)
HC3
HC2
—
HC1
—
HC3
HC4
HC2
—
TWE + (ZP)
HC3
Installation sequence
E2
E3
3
5
—
—
—
—
—
—
HC2
—
—
—
—
—
HC2
HC3
—
—
HC3
—
—
—
HC3
HC4
HC4
—
—
—
—
—
—
—
TWE
—
—
—
—
—
TWE
—
HC2
TWE
—
—
HC2
—
—
—
TWE
—
HC3
TWE
—
—
HC3
—
HC2
HC3
TWE
—
HC3
HC4
HC4
—
39