Viessmann Vitoligno 300-C Installation And Service Instructions Manual page 173

18 to 48 kw pellet boiler
Table of Contents

Advertisement

Specification
Rated heating output range
Rated voltage
Rated frequency
Rated current
Power consumption (arithmetic mean)
Protection class
IP rating to EN 60529; ensure through design/installation
Type of operation to EN 60730-1
Permiss. ambient temperature
During operation
(Installation in living spaces or boiler rooms, standard
ambient conditions)
During storage and transport
Rated relay output breaking capacity at 230 V
Heating circuit pumps
Circulation pump for cylinder heating
Solar circuit pump, as alternative to heating circuit pump
M2
DHW circulation pump
Central fault message
Mixer motor
Discharge motor, room discharge/silo, mole
Required draught (at full load)
Max. permiss. draught
*17
Flue gas
*18
Average temperature (gross)
At the upper rated heating output
At partial load (30 % of upper rated heating output)
CO
content in the flue gas
2
At the upper rated heating output
At partial load (30 % of upper heating output)
Mass flow rate
At the upper rated heating output
At partial load (30 % of upper rated heating output)
The boiler complies with the limits to EN 303-5
CE designation in accordance with the Machinery Direc-
tive
Boiler class to EN 303-5: 2012
Total max. 4
*16
Install a draught stabiliser (draught limiter) in the chimney.
*17
Calculation values for sizing the flue system to EN 13384.
*18
Actual flue gas temperature as average gross value in line with EN 304 at 20
*19
*19
kW
6 - 18
8 - 24 11 - 32 13 - 40
V
Hz
A
W
°C
°C
A
A
A
A
A
A
W
Pa
5
5
mbar
0.05
0.05
Pa
15
15
mbar
0.15
0.15
C
125
125
º
C
80
80
º
% by
13
13
vol.
% by
vol.
11
11
kg/h
46
65
kg/h
11
15
C combustion air temperature.
º
Specification
16 - 48
230
50
10
120
I
IP 20
Type 1 B
0 to +35
20 to +65
4 (2)
*16
4 (2)
*16
4 (2)
*16
4 (2)
*16
4 (2)
*16
0.2 (0.1)
*16
Max. 200
5
5
0.05
0.05
0.05
15
15
15
0.15
0.15
0.15
130
130
135
80
80
80
13
13
13
11
11
11
82
105
124
19
24
29
CE
5
173
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vl3c

Table of Contents