12) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
f Proceed to Step 17) when [OFF] is selected.
13) Press as to select [CALIBRATION TIME].
14) Press the <ENTER> button.
f The projector is in the adjustment mode (the time is blinking).
15) Press qw to select "hour" or "minute", and press as or the number (<0> - <9>) buttons to set a
time.
f Selecting "hour" allows setting of only the hour in increments of one hour, and selecting "minute" allows
setting of only the minute in increments of one minute between 00 and 59.
16) Press the <ENTER> button.
f [CALIBRATION TIME] is set.
17) Press as to select [CALIBRATION MESSAGE].
18) Press qw to switch the item.
f The items will switch each time you press the button.
[ON]
[OFF]
19) Press as to select [APPLY].
20) Press the <ENTER> button.
f When [CONSTANT MODE] is set to anything other than [OFF] and the <ENTER> button is pressed in
following cases, the brightness and color of the light source at that time is set as the correction target for the
brightness and white balance of the screen, and the automatic correction will start.
g When [CONSTANT MODE] is set to anything other than [OFF] for the first time after purchasing the
projector
g When [CONSTANT MODE] is set to anything other than [OFF] for the first time after executing the
[PROJECTOR SETUP] menu → [INITIALIZE] → [FACTORY RESET]
f When [CONSTANT MODE] was previously set to anything other than [OFF], and the correction target for
the brightness and the white balance is already set, pressing the <ENTER> button displays the confirmation
screen. Proceed to Step 21).
f When [LINK] is set to [GROUP A] to [GROUP D] and the <ENTER> button is pressed, the group name is
displayed on the screens of the projectors that have been set as the same group.
21) Press qw to switch the item.
f The items will switch each time you press the button.
[YES]
[NO]
22) Press the <ENTER> button.
f Starts the automatic correction.
Note
f When [CONSTANT MODE] is set to [AUTO] or [PC], keep the shutter function disabled (shutter: opened) for at least two minutes, since the
brightness sensor will measure the brightness and color of the light source after the [BRIGHTNESS CONTROL SETUP] setting has been
completed.
Chapter 4  Settings — [PROJECTOR SETUP] menu
Does not measure the brightness and color of the light source periodically.
Measures the brightness and color of the light source by the brightness sensor at the time specified
by [CALIBRATION TIME].
Displays the time to complete the measurement while the brightness and color of the light source are
measured by the brightness sensor.
Does not display a message during the measurement.
LINK
Maintains the previously set brightness and white balance as the correction target.
Reconfigures the current brightness and color of the light source as the correction target of the
brightness and white balance of the screen.