5 Setup and Wiring
Connecting
Connect the camera cable (Ethernet cable FHV-VNBX / FHV-VNLBX: sold separately) to the Ethernet
connector on the 3D vision sensor. Then connect it to the top of the two Ethernet connectors on the
sensor controller.
3D vision sensor
FH-SMDA-GS050B
Wiring
Wire the signal line of the camera I/O cable (FH-VSDX-BX / FH-VSDX-LBX: sold separately) with a
crimp terminal. Insulate unnecessary signal lines and avoid contact with other signal lines.
I/O cable connector
3D vision sensor
FH-SMDA-GS050B
Wire color of camera I/O cable
24VDC (For camera power supply)
0V (For camera power supply)
*1
Unused
*1
Unused
*1
Unused
*1
Unused
NC
5-12
Ethernet cable
FHV-VNBX / FHV-VNLBX
Ethernet connector
Signal name
FH Series Vision System Hardware Setup Manual for 3D Robot Vision (Z436-E1)
Camera I/O cable
FH-VSDX-BX / FH-VSDX-LBX
Brown
Blue
Yellow
Black
Red
Orange
Gray
Ethernet connector
Sensor Controller
FH-5050
Wire color