Omron FH Series Hardware Setup Manual page 86

Vision system
Hide thumbs Also See for FH Series:
Table of Contents

Advertisement

5 Setup and Wiring
2
Connect the wire and power source to the terminal block connector (male) depending on the
indicated terminal block connector.
Indicate of terminal
block connector
3
Insert the terminal block connector (male) to the terminal block connector (female) of Sensor
Controller.
4
Tightens and fix the left and right screws for the terminal block connector (male). (Recommend-
ed tightening torque: 0.7 to 0.8 N•m)
7.64
7.62
7.62
Recommended Power Source of Sensor Controller
Power source types for FH series differ depending on the number of cameras due to current consump-
tion differences. Refer to the following table to use the appropriate type.
5-6
+
Connect the DC output positive (+V) of 24 VDC power.
-
Connect the DC output positive (-V) of 24 VDC power.
Connect the earth.
Terminal block connector (female)
Terminal block connector (male)
22.81
FH Series Vision System Hardware Setup Manual for 3D Robot Vision (Z436-E1)
Function
(Unit: mm)
35.3
14.7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fh-5050Fh-smda-gs050b

Table of Contents