Omron FH Series Hardware Setup Manual page 70

Vision system
Hide thumbs Also See for FH Series:
Table of Contents

Advertisement

3 Configuration
 RS-232C Connection (Cable Length Up to 10 m)
FH-MT12
Analog RGB
A video signal cable and an operation signal cable are required to connect the Touch Panel Moni-
tor.
Signal
Video signal
Touch panel operation
signal
Wiring
The power terminal block for the Touch Panel Monitor is located on the back of it.
Connect a power supply of 24 VDC there.
24 VDC
Power supply
24 VDC
• Wire the power supply wires as short as possible. (Max.2 m)
• If UL's certification is required, use a UL class II power supply.
• Use the cables and crimping terminals with the specified dimensions.
Do not directly connect an electric wire that is simply twisted to the terminal block.
- Recommended wire size: AWG 13 to 22 (0.326 to 2.62 mm
- Terminal screw: M4 (Tightening torque: 1.0 N•m)
- Crimping Terminal
8.0 mm max.
3-22
Touch panel cable(RS-232C):
XW2Z-
D-Sub
Monitor cable: FH-VMDA
RS-232C
DVI-Analog Conversion Cable
USB Cable
RS-232C Cable
M4
Recommended model
by OMRON:
S8VS-03024
8.0 mm max.
FH Series Vision System Hardware Setup Manual for 3D Robot Vision (Z436-E1)
PP-1
DVI-A
RS-232C
DVI-I
FH controller
Cable
OK
OK
OK
2
)
2 m
5 m
10 m
OK
OK
OK
-
OK
OK

Advertisement