5. PARAMETERS
Classification
No.
Symbol
PS06
LB2
PS07
LB3
PS08
*LIT3
LPWM Magnetic pole detection voltage level
PS09
PS10
PS11
PS12
PS13
PS14
PS15
PS16
Name and function
Servo control speed deviation error detection level
Used to set the speed deviation error detection level of the servo control
error detection. When the difference between the model feedback
speed and the feedback speed is bigger than this setting value, the
servo control error is detected (42). (Refer to section 4.4)
Servo control to torque deviation error detection level
Used to set the torque deviation error detection level of the servo control
error detection. When the difference between the command torque and
the feedback torque is bigger than this setting value, the servo control
error is detected (42). (Refer to section 4.4)
Special function selection 3
Select the valid/invalid setting of the stroke limit and the magnetic pole
detection method for the magnetic pole detection. (Refer to section
4.2.3)
When the stroke limit (FLS and RLS) of the servo amplifier is not used,
invalidate the stroke limit for the magnetic pole detection.
0
1
Method selection for the magnetic pole detection
0: Position detection method
4: Minute position detection method
Valid/invalid setting of the stroke limit (FLS and
RLS) for the magnetic pole detection
0: Valid
1: Invalid
Used to set the direct current exciting voltage level during the magnetic
pole detection. When the overload alarm (50 and 51) or overcurrent
alarm (32) occurs, set the smaller value. When the initial magnetic pole
detection error occurs during the magnetic pole detection, set the bigger
value. (Refer to section 4.2.4)
For manufacturer setting
Do not change these values by any means.
5 - 10
Initial
Unit
Setting range
value
100
r/min
1 to 2000
100
1 to 1000
0010h
Refer to the
name and
function
column
30
0 to 100
0005h
0064h
01F4h
0000h
0000h
0000h
0000h

Advertisement