Mitsubishi Electric MELSERVO-J3 Series Instruction Manual page 138

Sscnet interface direct drive servo
Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

APPENDIX
(2) Structure
The control circuit provide safe separation to the main circuit in the servo amplifier.
(3) Environment
(a) Operate the servo amplifier at pollution degree 2 or 1 set forth in EN 60664-1. For this purpose, install
the servo amplifier in a cabinet which is protected against water, oil, carbon, dust, dirt, etc. (IP54).
(b) Environment
(4) Power supply
(a) This servo amplifier can be supplied from star-connected supply with earthed neutral point of
overvoltage category
for 1-phase supply, a reinforced insulating transformer is required in the power input section.
(b) For the interface power supply, use a 24VDC power supply with reinforced insulation on I/O terminals.
Molded-case
circuit breaker
MCCB
(Note 1)
Ambient temperature
Ambient humidity
Maximum altitude
Note 1. Ambient temperature is the internal temperature of the cabinet.
2. The servo amplifier 200V 3.5kW or less can be mounted closely. In this case, keep the
ambient temperature within 0 to 45
or less of the effective load ratio.
set forth in EN 60664-1. However, when using the neutral point of 400V system
App. - 7
Cabinet
Reinforced insulating type
Magnetic
contactor
MC
Item
[ ]
Operation
[ ]
[ ]
Storage,
[ ]
Transportation
Operation,
Storage,
Transportation
Operation,
Storage
Transportation
(32 to 113 ) or use the servo amplifier with 75
24VDC
power
supply
Direct drive motor
Servo
amplifier
M
Environment
(Note 2) 0 to 55
32 to 131
20 to 65
4 to 149
90
RH or less
1000m or less
10000m or less

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j3-b-rj080w seriesTm-rfm