Mitsubishi Electric MELSERVO-J3 Series Instruction Manual page 108

Sscnet interface direct drive servo
Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

6. TROUBLESHOOTING
Display
Name
E0
Excessive
regeneration
warning
E1
Overload
warning 1
E2
Direct drive
motor overheat
warning
E3
Absolute
position counter
warning
E4
Parameter
warning
E6
Servo forced
stop warning
E7
Controller
forced stop
warning
E8
Cooling fan
speed reduction
warning
E9
Main circuit off
warning
EC
Overload
warning 2
ED
Output watt
excess warning
Definition
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual.
Direct drive motor
1. Ambient temperature of direct drive
temperature rose and
motor is over 40
exceeded 85
of the
2. Direct drive motor is overloaded.
alarm occurrence
level.
3. Thermistor in direct drive motor is
faulty.
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual.
Cause
Check environment so that ambient
(104 ).
temperature is 0 to 40
1. Reduce load.
2. Check operation pattern.
3. Replace direct drive motor that provides
Replace the direct drive motor.
6 - 7
Action
(32 to 104 ).
larger output.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j3-b-rj080w seriesTm-rfm