5. PARAMETERS
5.3 Gain/Filter parameters (No.PB

5.3.1 Parameter list

No.
Symbol
PB01
FILT
Adaptive tuning mode(adaptive filter II)
PB02
VRFT
Vibration suppression control tuning mode(advanced vibration suppression
control)
PB03
For manufacturer setting
PB04
FFC
Feed forward gain
PB05
For manufacturer setting
PB06
GD2
Ratio of load inertia moment to direct drive motor inertia moment
PB07
PG1
Model loop gain
PB08
PG2
Position loop gain
PB09
VG2
Speed loop gain
PB10
VIC
Speed integral compensation
PB11
VDC
Speed differential compensation
PB12
For manufacturer setting
PB13
NH1
Machine resonance suppression filter 1
PB14
NHQ1
Notch shape selection 1
PB15
NH2
Machine resonance suppression filter 2
PB16
NHQ2
Notch shape selection 2
PB17
Automatic setting parameter
PB18
LPF
Low-pass filter setting
PB19
VRF1
Vibration suppression control vibration frequency setting
PB20
VRF2
Vibration suppression control resonance frequency setting
PB21
For manufacturer setting
PB22
PB23
VFBF
Low-pass filter selection
PB24
*MVS
Slight vibration suppression control selection
PB25
For manufacturer setting
PB26
*CDP
Gain changing selection
PB27
CDL
Gain changing condition
PB28
CDT
Gain changing time constant
PB29
GD2B
Gain changing ratio of load inertia moment to direct drive motor inertia
moment
PB30
PG2B
Gain changing position loop gain
PB31
VG2B
Gain changing speed loop gain
PB32
VICB
Gain changing speed integral compensation
PB33
VRF1B Gain changing vibration suppression control vibration frequency setting
PB34
VRF2B Gain changing vibration suppression control resonance frequency setting
)
POINT
For details of the parameters in which columns MR-J3- B is written, refer to the
MR-J3- B Servo Amplifier Instruction Manual section 5.2.
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
Never change the parameters for the manufacturer setting.
Name
5 - 5
Initial value
Unit
Reference
0000h
MR-J3- B
0000h
0
0
MR-J3- B
500
7.0
Multi-
MR-J3- B
plier
( 1)
24
rad/s
37
rad/s
823
rad/s
33.7
ms
980
0
4500
Hz
MR-J3- B
0000h
4500
Hz
0000h
3141
rad/s
100.0
Hz
100.0
Hz
0.00
0.00
0000h
MR-J3- B
0000h
0000h
0000h
MR-J3- B
10
1
ms
7.0
Multi-
plier
( 1)
37
rad/s
823
rad/s
33.7
ms
100.0
Hz
100.0
Hz