Viessmann Vitocal 200-S Installation And Service Instructions Manual page 115

Air source heat pump, split version for heating and cooling operation
Table of Contents

Advertisement

Specification
(cont.)
Type AWB/AWB-AC
Cooling capacity data to EN 14511
(A35/W18, 5 K spread)
Rated cooling capacity
Fan speed
Power consumption
Energy efficiency ratio EER in
cooling mode
Air intake temperature
Cooling mode (type AWB-AC)
Min.
Max.
Heating mode
Min.
Max.
Heating water (secondary cir-
cuit)
Content (excl. expansion vessel) l
Minimum flow rate (must be
maintained)
Minimum volume in the heating
system (cannot be fitted with
shut-off devices)
Max. external pressure drop
(RFH) at minimum flow rate
Max. flow temperature
External unit electrical values
Rated voltage, compressor
Max. operating current, com-
pressor
Starting current, compressor
Starting current, compressor
with stalled armature
MCB/fuse protection
IP rating
Internal unit electrical values
Heat pump control unit/PCB
Rated voltage, control
unit/PCB
MCB/fuse protection, power
supply
Internal fuse
Instantaneous heating water
heater
Only for type AWB-AC
Rated voltage
Heating output
MCB/fuse protection, power
supply
201.C10
kW
rpm
kW
°C
°C
°C
°C
l/h
l
mbar
kPa
°C
A
A
A
A
IP
kW
3 x B16A
201.C13
8.83
12.83
600
690
1.98
3.45
4.46
3.72
15
15
45
45
20
20
35
35
3.2
3.2
1600
1600
50
50
450
450
45
45
55
55
3/N/PE 400 V/50 Hz
7.85
9.89
10
10
16
16
16
16
X4
X4
1/N/PE 230 V/50 Hz
1 x B16A
6.3 A (slow)/250 V
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
8.8
8.8
3 x B16A
Specification
201.C16
14.22
690
4.23
3.43
15
45
20
35
3.2
1600
50
450
45
55
13.09
10
16
16
X4
8.8
3 x B16A