Viessmann Vitocal 200-S Installation And Service Instructions Manual page 113

Air source heat pump, split version for heating and cooling operation
Table of Contents

Advertisement

Specification
(cont.)
Type AWB/AWB-AC
Refrigerant circuit
Refrigerant
Refrigerant charge
Global warming potential
(GWP)
CO
equivalent
2
Top-up quantity for line lengths
12 m to
30 m
>
Compressor (hermetically
sealed)
Permiss. operating pressure
High pressure side
Low pressure side
External unit dimensions
Total length
Total width
Total height
Internal unit dimensions
Total length
Total width
Total height
Total weight
External unit
Internal unit type AWB
Internal unit type AWB-AC
Permissible operating pres-
sure, secondary side
Connections
Heating water flow
Heating water return and DHW
cylinder return
DHW cylinder flow
Liquid line
Pipe
7
Internal unit
External unit
Hot gas line
Pipe
7
Internal unit
External unit
Max. line length, liquid line, hot
gas line
201.B04
201.B05
R410A
kg
1.2
2088
t
2.51
g/m
20
Type
Rotating
Rotating
piston
piston
bar
43
MPa
4.3
bar
43
MPa
4.3
mm
290
mm
869
mm
610
mm
360
mm
450
mm
905
kg
43
kg
34
kg
38
bar
3
MPa
0.3
G
1
¼
G
1
¼
G
1
¼
mm
6 x 1
UNF
⁷⁄₁₆
UNF
mm
12 x 1
UNF
UNF
¾
m
20
201.B07
201.B10
R410A
R410A
2.15
2.15
2088
2088
4.50
4.50
60
60
Rotating
Scroll
piston
43
43
4.3
4.3
43
43
4.3
4.3
340
340
1040
1040
865
865
360
360
450
450
905
905
66
66
34
34
38
38
3
3
0.3
0.3
1
1
¼
¼
1
1
¼
¼
1
1
¼
¼
10 x 1
10 x 1
16 x 1
16 x 1
30
30
Specification
201.B13
R410A
R410A
2.95
2.95
2088
2088
6.20
6.20
60
60
Scroll
43
43
4.3
4.3
43
43
4.3
4.3
340
340
975
975
1255
1255
360
360
450
450
905
905
110
110
37
37
42
42
3
3
0.3
0.3
1
1
¼
¼
1
1
¼
¼
1
1
¼
¼
10 x 1
10 x 1
16 x 1
16 x 1
30
30