Technical Data

Interfaces

Interface
DTE
ISDN
Analog ports
Power Fail ports
ISDN
Data Rates
Telephone
LAN
WAN
Audio
External
Control
IP Office (R2.1) Installation Manual
40DHB0002UKCL – Issue11c (19th November 2004)
Information
25 way D-Type female connector, V.24/V.28. (9 way D-type on IP406V2 and IP412).
ROW Interfaces:
BRI :
RJ45 sockets. ETSI S/T Interface to CTR3 for Pan European Connection.
PRI E1:
RJ45 socket. ETSI T Interface to CTR4 for Pan European Connection.
PRI E1-R2: RJ45 socket. ETSI T Interface to CTR4 for Pan European Connection.
PRI E1-R2: 75Ω BNC Coax.. ETSI T Interface.
PRI T1:
RJ45 socket: FCC Part 68/JATE connection.
USA Interfaces:
PRI T1 Service:
Ground Start (GS) – Default, E&M, 56k data for 5ESS, 56/64/64 restricted for 4ESS
PRI ISDN Switch support:
4ESS, 5ESS, DMS-100, DMS-250 (includes conformance to ANSI T1.607 & Bellcore
Special Report SR4287, 1992
PRI ISDN Services:
AT&T Megacom 800, AT&T WATS (4ESS), AT&T SDS Accunet 56kB/s & 64kB/s (4ESS),
AT&T Multiquest (4ESS).
RJ45 sockets: Loop start/Ground start (region dependant)
RJ45 sockets: telephone ports act as master sockets
BRI: B-channel 64kbps or 56kbps, D-channel 16kbps.
PRI: B-channel 64kbps or 56kbps, D-channel 64kbps.
RJ45 sockets. EU - Telephone ports act as master sockets.
CLI Schemes: DTMFA, DTMFC, DTMFD, FSK and UK20.
REN = 2
Off Hook current = 25mA.
Ring Voltage = 40V (nominal) RMS.
External Bell (via analog port); REN = 1
RJ45 sockets. Auto-negotiating 10/100BaseTX Ethernet (10/100Mbps).
Port 8 is MDI/MDIX switchable via the adjacent Cascade pushbutton switch.
Refer to pages 7, 11 and 15.
37 way D-Type female sockets. X.21 interface to 2048k bps, V.35 interface to 2048k bps and
V.24 Interface to 19k2 bps.
3.5mm Stereo Jack socket. Input impedance - 10k /channel.
Maximum a.c. signal – 200mV rms.
3.5mm Stereo Jack socket. Switching Capacity - 0.7A.
Maximum Voltage - 55V d.c. On state resistance - 0.7Ω.
Short circuit current - 1A. Reverse circuit current capacity - 1.4A.