Technical Data

Technical Specifications

General

Dimensions
(unboxed)
Dimensions
(boxed)
Environmental
Weight (unboxed)
Kgs
lbs
Weight (boxed)
Kgs
lbs
Power Supply
Consumption
(nominal Watts)
Lump-in-Line PSU

Interfaces

Interface
DTE
ISDN
Analog ports
Power Fail ports
ISDN
Data Rates
Telephone
LAN
WAN
Audio
External
Control
IP Office Installation Manual
40DHB0002UKCL – Issue 9 (28 October 2003)
IP401:
IP403/6/12 & Exp. Modules : Width: 445mm (17.5") Height: 71mm (2.8")
IP401:
IP403/6/12 & Exp. Modules : Width: 445mm (17.5") Height: 71mm (2.8")
0 to +40°C. 95% relative humidity, non-condensing.
401 403 406 412
Analog16
1.2
2.6
3.0
3.0
2.6
5.8
6.6
6.7
401 403 406 412
Analog16
2.4
3.85 4.3
4.3
5.4
8.6
9.6
9.6
2.5mm DC inlet socket. 24Vdc Power input. Rating 24Vd.c., 2A max.
401
403
406412
Analog16
24
26
16 17.5
Power Requirements: I/P 100-240Vac, 50/60Hz, 81-115VA, Input current 2A max
Standard PSUs: O/P 24Vdc, 1.875A, output power 45W max.
DS30 80W PSU: O/P 16Vdc, 5A, output power 80W max.
Lump-in-line PSUs are CE/UL/Dentori Safety Approved.
Information
25 way D-Type female connector, V.24/V.28. (9 way D-type on IP412s)
ROW Interfaces:
BRI :
RJ45 sockets. ETSI S/T Interface to CTR3 for Pan European Connection.
PRI E1:
RJ45 socket. ETSI T Interface to CTR4 for Pan European Connection.
PRI E1-R2: RJ45 socket. ETSI T Interface to CTR4 for Pan European Connection.
PRI E1-R2: 75Ω BNC Coax.. ETSI T Interface.
PRI T1:
RJ45 socket: FCC Part 68/JATE connection.
USA Interfaces:
PRI T1 Service:
Ground Start (GS) – Default, E&M, 56k data for 5ESS, 56/64/64 restricted for 4ESS
PRI ISDN Switch support:
4ESS, 5ESS, DMS-100, DMS-250 (includes conformance to ANSI T1.607 & Bellcore
Special Report SR4287, 1992
PRI ISDN Services:
AT&T Megacom 800, AT&T WATS (4ESS), AT&T SDS Accunet 56kB/s & 64kB/s (4ESS),
AT&T Multiquest (4ESS).
RJ45 sockets: Loop start/Ground start (region dependant)
RJ45 sockets: telephone ports act as master sockets
BRI: B-channel 64kbps or 56kbps, D-channel 16kbps.
PRI: B-channel 64kbps or 56kbps, D-channel 64kbps.
RJ45 sockets. EU - Telephone ports act as master sockets.
CLI Schemes: DTMFA, DTMFC, DTMFD, FSK and UK20.
REN = 2
Off Hook current = 25mA.
Ring Voltage = 40V (nominal) RMS.
External Bell (via analog port); REN = 1
RJ45 sockets. Auto-negotiating 10/100BaseT Ethernet (10Mbps).
Port 8 is MDI/MDIX switchable via the adjacent Cascade pushbutton switch.
Refer to pages 11, 15 and 19.
37 way D-Type female sockets. X.21 interface to 2048k bps, V.35 interface to 2048k bps and
V.24 Interface to 19k2 bps.
3.5mm Stereo Jack socket. Input impedance - 10k /channel.
Maximum a.c. signal – 200mV rms.
3.5mm Stereo Jack socket. Switching Capacity - 0.7A.
Maximum Voltage - 55V d.c. On state resistance - 0.7Ω.
Short circuit current - 1A. Reverse circuit current capacity - 1.4A.
Width: 255mm (10").
Width: 304mm (13.4") Height: 105mm (4.2") Depth: 305mm (12")
DT/DS16 DT/DS30
2.9
3.0
3.50
6.5
6.7
7.8
DT/DS16 DT/DS30
4.2
4.3
4.8
9.4
9.6
10.8
DT/DS16 DT/DS30
5
24
30
Technical Specifications - Page 79
Height: 71mm (2.8")
Depth: 235mm (9.3")
Depth: 245mm (9.7")
Depth: 245mm (9.7")
WAN3 So8
Phones8 ...16 ...30
2.8
2.8
2.8
6.3
6.3
6.3
WAN3 So8
Phones8 ...16 ...30
4.1
4.1
4.1
9.2
9.2
9.2
WAN3 So8
Phones8 ...16 ...30
12
24
12
Technical Data - Page 79
Technical Specifications
2.9
3.10
6.5
6.94
4.2
4.4
9.4
9.7
16
30