VR 21
NOTICE
Use only shielded cables and metallic or conductive connector/coupling covers
with large-area shield support.

9.3 DC 24 V Voltage Supply

Cables with a cross section of 0.75 to 2.5 mm
tion terminal.
Fig. 9-2: Power supply connector X1
Pin
Designation
1
2
0 V
3
24 VDC
Use a 24 V industrial power supply unit acc. to DIN EN 60742, classification VDE
0551, for example "VAP01.1H-W23-024-010-NN" (parts number R911171065) for
the voltage supply.

9.4 USB Interfaces X9, X10

Two USB host interfaces are available at the operating device.
Operation of the USB ports at the operating device
When using input devices not intended for industrial use (e.g. key-
board, mouse), the operational safety is limited. Input devices inten-
ded for home or office use are also part of the devices not intended
for industrial use.
Connect only USB devices that meet the USB2.0 specification.
For the specification of a suitable cable, refer to "Universal Serial
Bus Specification Rev. 2.0".
The max. cable length is 2.5 m.
DOK-SUPPL*-VR21**.01**-IT02-EN-P
Malfunctions due to insufficient shielding!
2
can be connected to the connec-
X1
1 2 3
Function
Low-noise earth, functional earth (FE)
Supply voltage 0 V (GND)
24 VDC supply voltage
Bosch Rexroth AG
Interfaces