Power Supply Installation

Purpose
Power Supply Enclosure is part of the complete Bioshield™ UV Disinfection System.
Frequency
Required with new construction, retro-fit or replacement of outdated equipment.
Parts and Required Equipment
• Set of Slot and Phillips Head Screwdrivers
• Adjustable Wrench
• Pliers
• Wall Struts or Braces
• Supplied Enclosure Mounting Hardware
• Personal Safety Equipment
General risk due to suspended load.
General risk due to electricity.
General risk due to pressurized piping or UV Vessel.
Procedure
1. Use the supplied enclosure mounting feet if the Power Supply Enclosure is going to be mounted on a wall.
2. Mount the Power Supply Enclosure close to the UV Vessel so that the lamp cables reach between the Power Supply
Enclosure and the UV Vessel. The power supply lamp cables are approximately 10 - 20' long to provide an adequate
routing length from the power supply enclosure to the UV vessel. Keep in mind that the temperature & UV sensors
have approximately 12' long cables, so the power supply should be placed within this length constraint to avoid the
additional requirement of sensor extension cables.
3. The Power Supply Enclosure should be mounted so that the controls are visible to the operator. The location used for
mounting the Power Supply Enclosure should be as dry and cool as possible.
4. The Power Supply Enclosure should be located in a place that provides sufficient weather protection, in the case of
outdoor installation. Sufficient space near the cooling fan's intake and exhaust must be provided.
5. The Power Supply Enclosure must be supplied with the correct operating voltage (120/230 VAC). Electrical requirement
information is located on the Power Supply Enclosure labeling and can be found on Page 8 (Dimensions and Electrical
Specifications) of this manual. Failure to supply the UV System with the correct operating voltage can damage the
ballasts and other electrical hardware. Use only a well-ground electrical circuit.
6. The UV System is equipped with an equipment-grounding conductor and a grounding plug. The grounding plug must
be installed and grounded in accordance with all local codes and ordinances. Improper connection of the equipment-
grounding conductor can result in electrocution. Check with a qualified electrician or service personnel if you question
whether the equipment is properly grounded.
7.
Input power to the Power Supply Enclosure is switched on and off using the enclosure's
External On/Off switch or optional Remote On/Off control.
Note: All UV control enclosures that utilize our microprocessor controls should be mounted with considerations to
other devices that emit, or are suspected of emitting, any EMI & RFI noise and that any sensors used in conjunc-
tion with our microprocessor controls should use industry standard procedures to avoid EMI & RFI noise issues.
BIOSHIELD™ Commercial UV Disinfection System Installation and User's Guide
13

Hide quick links: