18
Note: Each Lamp cable (1) is equipped with a Water Tight Connector (2). This
cable adapter is made up of three components: Nut (3), Rubber Gasket (4)
and Male-Threaded Body (5).
3.
Loosen (not remove) the lamp Water Tight Connector nut (3) to release tension on the lamp cable allowing the cable to
slide freely through the adapter. This will allow the male-threaded body (5) portion of the lamp Water Tight Connector to
be threaded into the white quartz sleeve retaining nut without twisting the lamp cable (after lamp installation).
4. With the UV lamp installed inside the quartz sleeve and six inches exposed,
attached the lamp cable's stepped 4-Pin Connector on to the four pins of the
UV lamp.
5. With the lamp cable/lamp connection complete gently slide the remainder of the lamp w/ cable through the Quartz
Sleeve Retaining Nut and into the quartz sleeve. With the lamp now inside the quartz sleeve, gently continue to push
the lamp (w/ connected lamp cable) into the quartz sleeve until it stops, then pull out 1/2" of the lamp cable. This will
position the lamp properly inside the quartz sleeve avoiding heat damage to the Quartz Sleeve Module Faceplate and
Quartz Sleeve Module.
6. With the UV lamp in its correct position inside the quartz sleeve, thread the water tight
connector into the Quartz Sleeve Retaining Nut.
7. With the "black" Water Tight Connector threaded into the Quartz Sleeve Retaining Nut,
tighten the Cable Adapter Nut (3) to create a watertight seal on the lamp's cable. Take
care not to bend or damage the Water Tight Connector's "gasket prongs" during this
process.
8. The UV lamp is now properly installed.
BIOSHIELD™ Commercial UV Disinfection System Installation and User's Guide