Power Enclosure

The Remote Power Enclosure houses all components used for operation, monitoring and control of the entire Bioshield™
UV Disinfection System (monitoring and control vary depending on model). The power enclosure is designed for remote
mounting from the vessel and is equipped with 12' lamp cables and mounting hardware.
Microprocessor Controller Models
Features:
1. Microprocessor Controller Power Enclosure
2. Liquid Crystal Display Screen
3. Touch Pad Control
4. External On/Off Switch
5. Main Power Cable
6. Temperature Sensor
7. UV Intensity Sensor
8. Lamp Field Safety Cover Cable
9. Lamp/Power Cables
2
3
4
NOTE:
THE TEMP. SENSOR CABLE MUST BE CONNECTED
FOR THE POWER ENCLOSURE TO OPERATE.
by
WARNING:
reading and understanding the Operator's Manual thoroughly.
WARNING:
WARNING:
codes. Disconnect power before attempting to service unit. See the Operator's Manual for proper procedures.
WARNING:
DO NOT operate unit in no-flow situations.
CAUTION:
approved disinfection chemicals to impart residual concentrations.
NOTE:
Sleeve Seals every 9,000 hours or when replacing the lamps. For reliable performance, use only genuine Emperor Aquatics, Inc.
UV lamps and replacement parts.
Emperor Aquatics, Inc. - 2229 Sanatoga Station Road, Pottstown, PA. 19464
BIOSHIELD™ Commercial UV Disinfection System Installation and User's Guide
1
COOLING FAN
NOTE:
CLEAN FILTER MATS REGULARLY
TO AVOID OVERHEATING AND DAMAGE.
Model #:
No. of Lamps / Part #:
/
No. of Quartz Sleeves / Part #:
/
Maximum Design Flow Rate:
UV System Serial #:
Model Description:
Max. Operating Pressure:
Input Power:
Short Circuit Current Rating:
2KVA RMS 277 VAC MAX
Power Supply:
TYPE #2 ENCLOSURE
DO NOT operate this equipment without
Protect eyes and skin from direct exposure to UV Light.
Dangerous Voltage can cause severe or fatal injury. Install this equipment in accordance with all local electrical
Ensure that any trapped air is properly relieved from the unit, failure to do so will affect the unit's performance.
WARNING:
HAZARDOUS VOLTAGE CAN CAUSE
SEVERE OR FATAL INJURY. MUST BE INSTALLED
This equipment (UV Sterilizer) is designed for supplemental disinfection and should be used with registered or
ACCORDING WITH LOCAL ELECTRICAL CODES.
DISCONNECT POWER BEFORE ATTEMPTING TO
Replace UV lamps after 9,000 hours of continuous operation or as stated in the Operator's Manual. Replace the Quartz
SERVICE UNIT. SEE INSTRUCTIONS FOR PROPER
PROCEDURES.
For Warranty, Repair and Replacement Part Requests:
Please call 610–970–0440
or e-mail us at info@emperoraquatics.com
MAIN DISCONNECT AND BRANCH CIRCUIT
PROTECTION TO BE PROVIDED BY OTHERS
5
6
7 8
9
7