Lamp Field Safety Cover Installation - Pentair BIOSHIELD CLP41A6-XN Installation And User Manual

Commercial uv disinfection system
Table of Contents

Advertisement

Installation of Lamp Field Safety Cover
Purpose
To instruct the operator how to properly install the Lamp Field Safety Cover.
Frequency
Required anytime the lamp field is accessed.
Parts and Required Equipment
• Lamp Field Safety Cover
• Pliers
• Personal Safety Equipment
General risk due to electricity.
Procedure
1. With the UV lamps and lamp cables installed hand loosen the four Safety Cover Retaining
Screws from the QSM Faceplate so they have approximately 3/8" of clearance between the
head of the screw and the QSM Faceplate.
2. The Lamp Field Safety Cover uses a twist-lock attachment method that can only be
installed one way. Take the cover assembly with the cable slot facing downward and align
the four slotted keyways on the cover's flange face with the retaining screws on the QSM
Faceplate. Then place the cover over the screws and turn counterclockwise to engage the
retaining screws.
3.
Once the cover is in place, tighten the four Retaining Screws down until the cover is snugly held in place.
4. With the cover installed on the vessel, connect the Lamp Field Safety Cover cable that
is attached to the power supply to the connector that is located on the end of the Safety
Cover.
Note: The Lamp Field Safety Cover must be installed onto the vessel with its respective cable, located on the Power
Supply Enclosure, properly connected to its respective port on the Safety Cover. Removing the Lamp Field Safety Cover
or the cable connection will automatically shut off the UV system's lamp field and generate an alarm signal.
BIOSHIELD™ Commercial UV Disinfection System Installation and User's Guide