Microprocessor Controller Power Supply Operation
Operation
The operation of the Bioshield™ UV Disinfection System may only be carried out by authorized personnel. The
personnel responsible for the operation of this system must read and understand Section 10, Section 2 (Health & Safety
Precautions), and strictly comply with all relevant rules for accident prevention and local health and safety regulations.
Check all relevant safety measures before you switch on the UV system.
Microprocessor Controller Power Supply Enclosure
Operating Modes
Generally, the UV system is operated in "LOCAL" mode. An optional, discrete input circuit is provided to allow for either
"LOCAL/REMOTE" or "LOCAL" mode. If this option has been ordered there are two terminal blocks (brown) located inside
the Power Supply Enclosure. The UV system is supplied with both the brown terminals jumped together as the default
"ON" setting. To operate the UV system in the "REMOTE" mode, the "Factory-Installed Jumper" must be removed. Both the
brown terminals need to be wired to an external switch (not included) capable of handling 120/230-volt AC @ 1-amp.
Switches
The UV system Power Supply Enclosure is equipped with an External "Main Power" ON/OFF Switch.
With the Main Power ON/OFF Switch in the "On" position, power is supplied to the
Microprocessor Controller/Monitor, and the UV lamps.
With the Main Power ON/OFF Switch in the "Off" position, power is cut-off from the
entire UV system.
Note: The Main Power Switch must be in the "On" position if the optional Remote
On/Off feature is being used.
Microprocessor Controller Power Enclosure
1. Microprocessor Controller Power Enclosure
2. Liquid Crystal Display Screen
3. Touch Pad Control
4. External On/Off Switch
5. Main Power Cable
6. Temperature Sensor
7. UV Intensity Sensor
8. Lamp Field Safety Cover Cable
9. Lamp/Power Cables
The Text Display shows the current operating
status of the UV system that includes the
following parameters:
• Lamp Operating Status
• UV Intensity (UV%)
• Temperature
2
3
• Lamp Operating Hours
• Voltage Range
BIOSHIELD™ Commercial UV Disinfection System Installation and User's Guide
1
4
COOLING FAN
NOTE:
CLEAN FILTER MATS REGULARLY
TO AVOID OVERHEATING AND DAMAGE.
NOTE:
THE TEMP. SENSOR CABLE MUST BE CONNECTED
FOR THE POWER ENCLOSURE TO OPERATE.
Model #:
No. of Lamps / Part #:
/
No. of Quartz Sleeves / Part #:
/
Maximum Design Flow Rate:
UV System Serial #:
Model Description:
Max. Operating Pressure:
by
Input Power:
Short Circuit Current Rating:
2KVA RMS 277 VAC MAX
Power Supply:
TYPE #2 ENCLOSURE
WARNING:
DO NOT operate this equipment without
reading and understanding the Operator's Manual thoroughly.
WARNING:
Protect eyes and skin from direct exposure to UV Light.
WARNING:
Dangerous Voltage can cause severe or fatal injury. Install this equipment in accordance with all local electrical
codes. Disconnect power before attempting to service unit. See the Operator's Manual for proper procedures.
WARNING:
Ensure that any trapped air is properly relieved from the unit, failure to do so will affect the unit's performance.
WARNING:
DO NOT operate unit in no-flow situations.
SEVERE OR FATAL INJURY. MUST BE INSTALLED
CAUTION:
This equipment (UV Sterilizer) is designed for supplemental disinfection and should be used with registered or
approved disinfection chemicals to impart residual concentrations.
ACCORDING WITH LOCAL ELECTRICAL CODES.
NOTE:
Replace UV lamps after 9,000 hours of continuous operation or as stated in the Operator's Manual. Replace the Quartz
DISCONNECT POWER BEFORE ATTEMPTING TO
Sleeve Seals every 9,000 hours or when replacing the lamps. For reliable performance, use only genuine Emperor Aquatics, Inc.
SERVICE UNIT. SEE INSTRUCTIONS FOR PROPER
UV lamps and replacement parts.
PROCEDURES.
For Warranty, Repair and Replacement Part Requests:
Please call 610–970–0440
or e-mail us at info@emperoraquatics.com
MAIN DISCONNECT AND BRANCH CIRCUIT
Emperor Aquatics, Inc. - 2229 Sanatoga Station Road, Pottstown, PA. 19464
PROTECTION TO BE PROVIDED BY OTHERS
5
6
7 8
9
SECTION TEN
OPERATION
HAZARDOUS VOLTAGE CAN CAUSE
21