Section 13: Troubleshooting - Pentair BIOSHIELD CLP41A6-XN Installation And User Manual

Commercial uv disinfection system
Table of Contents

Advertisement

SITUATION
UV system will not function
with the External ON/OFF
Switch in the "On" position
UV Lamp does not light
UV Intensity too low
Enclosure Over-Heating
Quartz Sleeve Seal Failure
INSPECT FOR:
1. No Input Voltage Available
2. Temperature Sensor Cable Plug is Interrupted/Defective
3. Input Voltage is lower than the Factory Set Threshold
1. Faulty Contact (four-pin connector/lamp pins)
2. Defective Electronic Ballast
3. Defective UV Lamp
4. Water Damage due to Quartz Sleeve Seal Failure
1. Decreased UV Transmissibility
2. UV Lamp reached "End of Life"
3. Quartz Sleeve Fouled
4. Faulty UV Sensor
1. Ambient Temperature above 145º F
2. Defective Thermal Switch
3. Cooling Fan Filter Mat needs to be cleaned
4. Defective Cooling Fan
1. Cracked/Broken Quartz Sleeve
2. Failed Quartz Sleeve Retaining Nut O-Ring Seal
BIOSHIELD™ Commercial UV Disinfection System Installation and User's Guide
SECTION THIRTEEN
TROUBLESHOOTING
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents