Base Module (Or Tape Drive Expansion Unit Module) Power Supply; Required Tools; Replacing A Power Supply - HP E Series User Manual

Hide thumbs Also See for E Series:
Table of Contents

Advertisement

6.
Close the back door of the library.
7.
Use the Interface Manager CLI or the HP StorageWorks Command View TL to verify detection of the
new controller, and to perform configuration and firmware updates, if necessary.
The interface controller replacement procedure is complete.

Base module (or tape drive expansion unit module) power supply

375815-001
Part number
Primary or redundant power supply in the base module or the tape drive expansion
Location
unit
Characteristics
Provides power to base module and tape drive expansion module.
Function
Power Supply

Required tools

A Torx T-15 screwdriver is required for this procedure.

Replacing a power supply

To remove a power supply from the base module or expansion module:
1.
Open the back door of the library.
2.
Identify the power supply to be replaced.
3.
Remove power to the library by turning off the library main power switch (see
NOTE:
If the faulty power supply is redundant, the library does not have to be powered off during this
procedure.
4.
Unplug the power supply power cord that is connected to the AC power strip.
Hot-swappable
Input rating: 100–240 VAC / 50-60 Hz / 7.2A
Output rating: +3.3 VDC, +5 VDC, +12 VDC, -12 VDC
360 Watts total output power
10465
Figure 48
Enterprise Modular Library E-Series user guide
on page 69).