Robotics problems

Table 19
describes corrective actions for robotics problems.
Table 19

Robotics problems

Problem
The robot does not move at power on.
The picker partially grips a tape cartridge.
The bar code reader fails.
The robot times out or hangs.
The robot fails during an operation.
The robot drops a cartridge.
78
Maintenance
Corrective action
Verify that all internal shipping restraints have been removed.
Check that the library front door is closed.
Review latest error messages in the critical and warning event
logs to help decipher the message and determine the cause.
Issue a Move Tape command using the OCP to move the
cartridge from the picker to an empty storage bin.
Review latest error messages in the critical and warning event
logs to help decipher the message and determine the cause.
Power cycle the library.
Use the OCP to open the library doors and:
Verify that nothing obstructs the reader.
Verify that nothing is obstructing the robot.
Verify that all tape cartridges are fully inserted into the
storage slots and no tapes are lying on the library floor.
Check that approved bar code labels are being used and
are correctly applied.
Close the library doors to recalibrate the library.
Verify that nothing obstructs the robot.
Retry the operation.
Power cycle the library to recalibrate.
Review latest error messages in the critical and warning event
logs to help decipher the message and determine the cause.
Review latest error messages in the critical and warning event
logs to help decipher the message and determine the cause.
Use the OCP to open the library doors. Retrieve the cartridge,
orient it properly, and place the cartridge in an empty storage
bin. (Do not try to place the cartridge in the picker.)
Close the doors to perform an inventory.