Mitsubishi MELSEC QS Series User Manual page 241

Hide thumbs Also See for MELSEC QS Series:
Table of Contents

Advertisement

APPENDICES
(2) Ethernet functions which can be used in the safety CPU module
TableApp.24 List of Ethernet functions and their availability in the safety CPU module
Using 4E frame
Communication using the
Using QnA-compatible 3E frame
MC protocol
Using A-compatible 1E frame
Communication using the fixed buffer (Procedure exist)
Communication using the fixed buffers (No procedure)
Communication using the random access buffer
Sending/receiving e-mail
Establishing/disconnecting a connection with an external device of
which data communication is performed (OPEN/CLOSE)
Reading receive data/writing send data using fixed buffer
communication (BUFRCV/BUFSND)
Reading receive data using fixed buffer communication (for interrupt
programs) (BUFRCVS)
Clearing/reading error information of the Ethernet module (ERRCLR/
ERRRD)
Reinitializaton of the Ethernet module (UINI)
Communication using
Reading/sending e-mails from/to other stations (MRECV/MSEND)
dedicated instructions
Reading/writing data from/to word device on another station (READ/
SREAD/WRITE/SWRITE)
Reading/writing data from/to word device on another station (ZNRD/
ZNWR)
Sending/receiving data (SEND/RECV)
Receiving data on another station (for interrupt program) (RECVS)
Transient request to another station (REQ)
File transfer (FTP server function)
Communication using the Web function
CC-Link IE controller network, MELSECNET/H, MELSECNET/10 relay communication
Router relay communication (Router relay function)
Existence check of external device
Communication using the pairing open method
Remote password check
Simultaneous broadcast
Communication with
TCP/IP
MELSOFT products using
UDP/IP
dedicated connections
Hardware test
Self-loopback test
Communication error storage
Ethernet diagnostics function using GX Developer
TableApp.24 lists the functions of Ethernet and their availability in the safety CPU
module.
Function
* 1: Available only for the Ethernet module whose serial number (first five digits) is "07082" or higher.
* 2: Data cannot be written to the safety CPU module from the CPU module on another station.
(
Appendix 7.1)
Appendix 6 Restrictions on Using Ethernet Module with Safety CPU
Clock data read/write
Remote RUN/STOP
: Available,
Module
9
10
Availability
*1
11
*2
*2
*1
: Not available
App
- 29